TROUBLESHOOTING & REPAIR

F-8

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

The "OUTPUT ON" and "MAL-

1. The pilot arc duty cycle has

Make sure operator is not

FUNCTION" or "FAULT" LED's

been exceeded.

The

exceeding pilot arc duty cycle.

blink in alternating order. No

machine should cool

down

 

 

pilot arc.

and the lights quit blinking in

 

 

 

20 seconds. The pilot arc

 

 

 

duty cycle is limited to 20 out

 

 

 

of 80 seconds except in spe-

 

 

 

cial circumstances such as

 

 

 

cutting expanded metal.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.