TROUBLESHOOTING & REPAIR

F-10

Observe Safety Guidelines

 

 

 

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

AIR FLOW PROBLEMS

 

 

The "MACHINE ON" LED is lit

1.

Check the air supply to the

1. With 60 PSI applied to the

but there is no response when

 

machine.

Make sure suffi-

 

machine the air pressure

the torch trigger is pulled. The

 

cient air pressure is supplied

 

switch should be “closed.”

"AIR PRESSURE" LED does

 

to the PRO-CUT 60.

If the

 

Check for continuity (less

not turn on. The fan runs nor-

 

air does not flow, the

 

than 1 ohm) between leads

mally. The “FAULT” LED

 

machine will not operate.

 

#319 to #323. See wiring

blinks.

2. Low air pressure will also

 

diagram.

 

 

 

 

 

result in a "no start" condi-

2. Check the air solenoid

 

 

tion.

With

the

machine in

 

(SV1) operation by apply-

 

 

"PURGE" adjust the air reg-

 

ing 115 VAC to the solenoid

 

 

ulator to 60 psi (413kPa)

 

leads.

 

 

minimum while air is flowing.

 

a. If the solenoid activates

 

 

"AIR

PRESSURE"

LED

 

and air flows, the solenoid

 

 

must be lit when the air is

 

is good.

 

 

flowing.

 

 

 

 

b. If the solenoid does not

 

3.

Check

the

operation

of the

 

activate, replace the

 

 

solenoid.

 

 

air solenoid by switching the

 

 

 

 

machine to "PURGE". If the

3. Check plug J10 on the

 

 

air pressure is sufficient the

 

Control Board for loose or

 

 

air should begin to flow and

 

faulty connections.

 

 

"AIR

PRESSURE"

LED

 

 

 

 

should

turn on.

Return to

4. The Control Board could

 

 

the "RUN" mode. If air does

 

be faulty. Replace.

 

 

not flow when the torch trig-

 

 

 

 

ger pulled, consult your local

 

 

 

 

Lincoln Authorized

Field

 

 

 

 

Service Facility.

 

 

 

 

 

4. Check torch consumables -

 

 

 

 

replace if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.

PRO-CUT 60