TROUBLESHOOTING & REPAIR

F-52

RETEST AFTER REPAIR

Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.

INPUT IDLE AMPS

INPUT VOLTS / HERTZ

MAXIMUM IDLE AMPS

 

 

208 / 60

4.4

 

 

230 / 60

4.0

 

 

460 / 60

2.0

575 / 60

1.6

 

 

MAXIMUM ACCEPTABLE OUTPUT VOLTAGE -

AT MINIMUM OUTPUT SETTING

Output Control at Minimum

26 Amps @ 43VDC

 

 

MINIMUM ACCEPTABLE OUTPUT VOLTAGE -

AT MAXIMUM OUTPUT SETTINGS

Output Control at Maximum

60 Amps @ 90VDC

 

 

RECOMMENDED METERS FOR MACHINE OUTPUT TESTS

VOLTMETER:

Analog type meter

PRO-CUT 60