TROUBLESHOOTING & REPAIR |
| |||||||
TROUBLESHOOTING GUIDE |
|
|
| Observe Safety Guidelines | ||||
|
|
|
|
|
|
| detailed in the beginning of this manual. | |
|
|
|
|
| ||||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| ||||
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION | ||||
|
|
|
|
|
|
| ||
|
|
|
| OUTPUT PROBLEMS |
|
| ||
Major Physical or Electrical |
| 1. |
| Contact | The | Lincoln |
|
|
Damage is Evident |
|
|
| Electric | Service | Dept. |
|
|
|
|
|
| or |
|
| ||
|
|
|
|
|
| |||
|
|
|
| |||||
No LEDs light when the | 1. | Make sure input voltage | 1. Make sure ON/OFF Power | |||||
ON/OFF Power Switch | is |
|
| corresponds to | machine | Switch (S1) is operating | ||
turned "ON". Machine is dead. |
|
| nameplate voltage. |
| properly. |
| ||
Fan is not running. |
|
|
|
|
|
|
|
|
|
| 2. | Make sure the reconnect | 2. Check the main transformer | ||||
|
|
|
| panel is configured properly | primary leads to the re- | |||
|
|
|
| for the input voltage being | connect panel | for loose or | ||
|
|
|
| applied to the | faulty connections. | |||
|
|
|
| (Single Phase). |
|
|
| |
|
| 3. |
| Check the input line fuses. | 3. Check the leads from the | |||
|
|
| ON/OFF Power Switch (S1) | |||||
|
|
|
| Replace if blown. |
| to the reconnect panel (T1 | ||
|
|
|
|
|
|
| and T2) for loose or faulty | |
|
|
|
|
|
|
| connections. |
|
|
|
|
|
|
|
| 4. Perform Main | Transformer |
|
|
|
|
|
|
| Test. The main transformer | |
|
|
|
|
|
|
| could be faulty. Check for | |
|
|
|
|
|
|
| an open or | grounded |
|
|
|
|
|
|
| primary winding. | |
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call