Section TOC

Master TOC

A-1

INSTALLATION

TECHNICAL SPECIFICATIONS - PRO-CUT 60

INPUT - SINGLE PHASE / 60 HERTZ ONLY

Return to

Return to

Standard Voltage

208/230/460

460/575

Input Current at

Rated Output

50/45/23

23/18

Codes

10112, 9819

10118, 10096

RATED OUTPUT

Return to Section TOC

Return to Master TOC

Duty Cycle

60% Duty Cycle

100% Duty Cycle

Current

Range

25-60 Amps

AMPS

60

45

OUTPUT

Open Circuit

Voltage

MIN

MAX

235VAC

280 VAC

Volts at Rated Amps

115

115

Pilot Current

22.5A (20 seconds out of 80 seconds)

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

RECOMMEND INPUT WIRE AND FUSE SIZES

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30oC or Less

 

AC Input

 

Fuse

Type 75oC

 

 

 

 

Voltage at

 

(Super Lag)

Copper Wire in Conduit AWG (IEC) Sizes

 

60 Hertz

 

Circuit Breaker

 

 

 

 

 

 

 

(Delay Type)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Input Supply Wires

 

1 Ground Wire

 

 

 

 

 

 

 

208/230

 

50 AMPS

#8 (8.4mm2)

 

#10 (5.3mm2)

460/575

 

25 AMPS

#10 (5.3mm2)

 

#10 (5.3mm2)

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL

DIMENSIONS

 

 

 

 

 

 

(INCLUDES LIFT BAIL AND UNDERCARRIAGE W/O HANDLE)

 

 

 

 

 

 

 

 

 

 

Height

 

Width

Depth

 

Weight

 

 

 

 

 

 

Including Machine

 

 

 

 

 

 

Torch Cable (Length)

 

 

 

 

 

 

 

 

 

34 in.

 

19 in.

22 in.

 

(25ft/7.6m)

(50ft/15.2m)

 

 

 

322 lbs.

329 lbs.

 

864 mm

 

483 mm

559 mm

 

 

 

 

146 kg.

149 kg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRO-CUT 60

Page 8
Image 8
Lincoln Electric SVM104-A service manual Installation, Technical Specifications PRO-CUT