E-3

THEORY OF OPERATION

Return to Section TOC

Return to Master TOC

FIGURE E.4 - High Voltage/High Frequency and By-Pass Circuit

 

Return to Section TOC

Return to Master TOC

 

Section TOC

Master TOC

HIGH VOLTAGE / HIGH

to

to

FREQUENCY AND BY-PASS

Return

Return

CIRCUIT

 

 

 

The control board passes the 115vac through the

torch terminal. This momentary burst of high fre-

 

 

CR2 relay contacts to the primary of the high volt-

quency is used to ignite the pilot arc.

 

 

age transformer. The secondary of the high volt-

 

 

 

 

 

age transformer delivers a high voltage to the

The by-pass board is necessary to prevent any

 

 

spark gap generator and also to the high frequen-

unwanted signals from interfering with the Pro-

 

 

cy transformer. The high frequency transformer

Cut 60 circuitry.

to Section TOC

to Master TOC

transfers the high frequency "spark" to the

 

 

 

 

 

 

 

 

Return

Return

 

NOTE: Unshaded areas of Block Logic

 

 

Diagram are the subject of discussion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRO-CUT 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 36
Image 36
Lincoln Electric SVM104-A service manual High Voltage / High