Section TOC

Master TOC

TROUBLESHOOTING & REPAIR

F-28

POWER BOARD TEST

Return to

Return to Master TOC

to Master TOC

H1

LEAD

H2

LEAD

C

LEADS

NEG

LEAD

#40

LEADS

MOUNTING1J21 SCREWS

 

 

 

J21

H1

 

40 G1

 

 

B

G2

 

 

 

H2

4J20

 

 

 

 

 

 

2J20

J20

1J20

 

 

C

NEG

#40

3J22 J22 1J22

4J222J22

POWER BOARD

L7941

Return to

Return

FIGURE F.11-Power Board Test Points

Return to Master TOC

TEST PROCEDURE

1. Connect input power to machine.

2.Turn ON/OFF Power Switch to OFF.

Test A: Test for 12 VAC voltage to Power Board

1.Locate and insert probes into Power Board Plug locations 1J22 (lead H4) and 3J22 (lead H3). See Figure F.11. Carefully insert the probes into

the lead cavity to make contact with the lead.

2.Turn ON/OFF Power Switch to ON.

a.If 12 VAC is NOT present, check Plug J22 for loose or faulty wiring.

bIf no loose or faulty wiring is

found, perform Main Transformer Test.

3.Turn ON/OFF Power Switch to OFF.

PRO-CUT 60

Page 69
Image 69
Lincoln Electric SVM104-A service manual Figure F.11-Power Board Test Points