Lincoln Electric SVM104-A service manual Capacitor Discharge Procedure

Models: SVM104-A

1 114
Download 114 pages 54.03 Kb
Page 54
Image 54

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-13

TROUBLESHOOTING & REPAIR

CAPACITOR DISCHARGE PROCEDURE

WARNING

Service and repair should be performed only by Lincoln Electric factory trained per- sonnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed.

Call (216) 383-2531 or (800) 833-9353 (WELD).

WARNING

Failure to follow this capacitor discharge procedure can result in electric shock.

PROCEDURE DESCRIPTION

This procedure must be performed before any test or removal procedure that does not require the machine to be electrically “hot.”

MATERIALS NEEDED

High resistance, high wattage resistor

( 25-1000 ohms, 25 watts minimum). Insulated pliers

Insulated gloves

DC Volt/Ohm meter (Multimeter)

PRO-CUT 60

Page 54
Image 54
Lincoln Electric SVM104-A service manual Capacitor Discharge Procedure