Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-43

TROUBLESHOOTING & REPAIR

SCR MODULE REMOVAL

WARNING

Service and repair should be performed only by Lincoln Electric factory trained per- sonnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed.

Call (216) 383-2531 or (800) 833-9353 (WELD).

CAUTION

Printed Circuit Boards can be damaged by static electricity.

REMOVAL/REPLACEMENT DESCRIPTION

This procedure will assist you in removing or replacing the SCR Modules.

MATERIALS NEEDED

4mm Allen-type wrench Static grounding strap Replacement SCR Module

Joint Compound: Lincoln T12837 or equivalent (Dow Corning 340).

PRO-CUT 60

Page 84
Image 84
Lincoln Electric SVM104-A service manual SCR Module Removal