F-40

TROUBLESHOOTING AND REPAIR

F-40

 

 

 

 

 

RETEST AFTER REPAIR

If a failed test indicates that any mechanical part that could affect the machine’s electrical characteristics must be replaced or if any electrical components are repaired or replaced, the machine must be retested and meet the following standards.

Wire Feed Speed Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 to 600 IPM

Gas Solenoid (If Used) . . . . . . . . . . . . . Must function when gun trigger is activated.

1CR Relay . . . . . . . . . . . . . . . . . . . . . . Must function when gun trigger is activated.

2CR Reed Switch . . . . . . . . . . . . . . . . . Must close when welding current is present.

LN-8