Lincoln Electric SVM132-A service manual 1CR Relay Test, Table F.2 Relay Test Terminal Connections

Models: SVM132-A

1 99
Download 99 pages 19.61 Kb
Page 69
Image 69

Return to Section TOC

Return to Master TOC

F-19

 

TROUBLESHOOTING AND REPAIR

F-19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1CR RELAY TEST (continued)

 

 

 

 

TABLE F.2 – RELAY TEST TERMINAL CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminals

 

Terminals

 

 

 

 

 

A&B

 

A&B

 

 

 

Terminals

 

Energized

 

De-energized

 

 

 

7-1

 

Open

 

Closed

 

 

 

7-4

 

Closed

 

Open

 

 

 

8-2

 

Open

 

Closed

 

 

 

 

 

 

 

 

 

 

 

8-5

 

Closed

 

Open

 

 

 

9-3

 

Open

 

Closed

 

 

 

9-6

 

Closed

 

Open

 

 

 

 

 

 

 

 

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

7.Measure the resistance across the contacts. A resistance of less than one ohm indicates that the con- tacts are closed. An infinite resis- tance indicates that the contacts are open. Energize the 24VDC power supply and measure the resistance again. Compare to the conditions given in Table F.2. If the readings do not match the table, the relay is faulty and should be replaced.

8.Repeat the above procedure for all of the contacts.

9.Re-install relay into the relay board.

10.Install the screws that secure the left side cover assembly.