Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-6

 

TROUBLESHOOTING AND REPAIR

F-6

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS (Continued)

 

 

 

 

 

 

 

 

The circuit breaker (5 amp)

1.

Check or replace the gun trigger

1.

Perform the Trigger

 

repeatedly trips when the gun trig-

 

and leads. Make sure the trigger

 

Transformer Test.

 

ger is activated.

 

 

leads are not shorted to the elec-

 

 

 

 

 

 

 

trode or work cables.

2.

Perform the Drive Motor Test.

 

 

 

2.

Disconnect any accessory that

3.

Remove the molex plug from the

 

 

 

 

may be connected to terminals

 

relay board. If the circuit breaker

 

 

 

 

#7 and #32A. See wiring dia-

 

continues to trip, the control

 

 

 

 

 

gram. If the problem is resolved,

 

board may be faulty. If the cir-

 

 

 

 

 

the accessory may be faulty.

 

cuit breaker does not trip, the

 

 

 

 

 

 

 

relay board may be faulty.

 

 

 

 

 

 

The circuit breaker (5 amp) trips

1.

Disconnect any kits or acces-

1.

Check the wiring harness leads

when power is applied to the LN-8.

 

sories that may be incorporated

 

#32, #32A, #31, and #531 for

 

Gun trigger is NOT activated.

 

in the LN-8. Be sure to install

 

shorts or grounds. See wiring

 

 

 

 

 

any necessary jumper plugs. If

 

diagram.

 

 

 

 

 

problem is resolved the fault may

 

 

 

 

 

 

 

be in the disconnected kit.

2.

Perform the Trigger

 

 

 

 

 

 

 

Transformer Test.

 

 

 

 

 

 

3.

Remove the molex plug from the

 

 

 

 

 

 

relay board. If the circuit breaker

 

 

 

 

 

 

continues to trip, the control

 

 

 

 

 

 

 

board may be faulty. If the cir-

 

 

 

 

 

 

 

cuit breaker does not trip, the

 

 

 

 

 

 

 

relay board may be faulty.

 

 

 

 

 

 

4.

Perform the Drive Motor Test.

 

 

 

 

 

The 1/2 amp fuse on the relay

1.

Check to make sure the correct

1.

Perform the Drive Motor Test.

board repeatedly fails.

 

 

input voltage (115VAC) is being

 

 

 

 

 

 

 

applied to the LN-8.

2.

Perform the Trigger

 

 

 

 

 

 

 

Transformer Test.

 

 

 

 

2. Very rapid and repetitive gun

 

 

 

 

 

 

 

triggering can possibly cause the

2.

The relay board may be faulty.

 

 

 

 

 

field fuse to fail.

 

 

 

 

 

 

 

 

The drive motor thermostat “opens”

1.

Check for mechanical restric-

1.

Perform the Drive Motor Test.

while welding.

 

 

tions in the wire feeding path.

 

 

 

 

 

 

 

This condition could cause the

 

 

 

 

 

 

 

motor to overheat.

 

 

 

 

 

 

2. The electrode may be rusty or

 

 

 

 

 

 

 

dirty. Clean or replace.

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-800-833-9353.

LN-8

Page 56
Image 56
Lincoln Electric SVM132-A service manual Transformer Test