TROUBLESHOOTING AND REPAIR

F-5

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS (Continued)

 

 

 

 

 

 

 

 

The wire feeds when the gun trig-

1.

Check the welding cables for

1.

The 1CR relay, located on the

 

ger is activated but there is no arc

 

loose or faulty connections.

 

power board, may be faulty.

 

voltage.

 

 

 

 

Check or replace. Note: The

 

 

 

 

2.

Put a jumper wire from #2 to #4

 

relay may operate but the indi-

 

 

 

 

 

on the power source terminal

 

vidual contacts may not be func-

 

 

 

 

strip. (machines with 14 pin

 

tioning properly.

 

 

 

 

 

amphenols pin C to pin D). If the

 

 

 

 

 

 

 

arc voltage is not present at the

2.

If a burnback kit is installed,

 

 

 

 

 

output terminals, the power

 

remove and install the jumper

 

 

 

 

 

source is faulty. If the arc volt-

 

plug. If the problem is solved,

 

 

 

 

 

age IS present, the problem is in

 

the burnback kit is faulty.

 

 

 

 

 

the wire feeder or control cable.

 

 

 

 

 

 

 

 

3.

Check the #2 and #4 leads in the

 

 

 

3.

Check the continuity of leads #2

 

LN-8 wiring harness for loose or

 

 

 

 

and #4 through the control cable.

 

faulty connections. See wiring

 

 

 

 

 

Replace if “open”.

 

diagram.

 

 

 

 

4. The welding gun may be faulty.

 

 

 

 

 

 

 

Check or replace.

 

 

 

 

 

 

 

 

 

The wire continues to feed with the

1.

Disconnect the gun trigger cable.

1.

The 1CR relay may be stuck

 

gun trigger open, and the wire is

 

If the problem is solved, the gun

 

closed. Perform the 1CR Relay

electrically “hot”. The interlock

 

trigger or cable is faulty. Repair

 

Test.

 

switch is in the “off” position.

 

or replace.

 

 

 

 

 

 

 

 

2.

Check the relay board. Replace

 

 

 

 

 

 

if faulty.

 

 

 

 

 

 

 

With the interlock switch (S2) in the

1.

Check leads #529 and #528 for

1.

The 2CR reed switch may be

 

“ON” postion, the wire feed stops

 

loose or faulty connections

 

faulty. Check to see if it closes

when the gun trigger is released.

 

between the 2CR reed switch

 

when welding.

 

 

 

 

 

and the control board and motor

 

 

 

 

 

 

 

thermal circuit breaker. See

2.

Check the interlock switch (S2)

 

 

 

 

wiring diagram.

 

for proper operation.

 

 

 

 

 

 

3.

Check the continuity (zero ohms)

 

 

 

 

 

 

of leads #523 and #536 between

 

 

 

 

 

 

the interlock switch (S2) and the

 

 

 

 

 

 

relay board. See wiring diagram.

 

 

 

 

 

4.

The relay board may be faulty.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-800-833-9353.