F-27

TROUBLESHOOTING AND REPAIR

F-27

 

 

 

 

 

CIRCUIT BREAKER REPLACEMENT (continued)

FIGURE F.8 – CIRCUIT BREAKER AND GROUND LEAD PROTECTOR REPLACEMENT

SCREW CIRCUIT

BREAKER

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

GROUND LEAD

PROTECTOR SWITCH

SWITCH

MOUNT

FLATWASHER

LOCKWASHER

NUT

REPAIR PROCEDURE

1.Using the 5/16 in. nutdriver, remove the screws from the left side cover assembly.

2.Tag and remove the two connec- tors from the back of the circuit breaker. Refer to Figure F.8.

3.Using the 9/16 in. wrench, remove the retaining nut that secures the circuit breaker to the center panel

LN-8

RETAINING

NUT

on the wire feeder. Remove the circuit breaker from the wire feeder.

4.Install the new circuit breaker through the panel of the control box. Secure the circuit breaker with the retaining nut.

5.Install the connectors onto the back of the circuit breaker at the positions they were removed from.

6.Install the screws that secure the left side cover assembly.