F-23

TROUBLESHOOTING AND REPAIR

F-23

 

 

 

 

 

DRIVE MOTOR TEST (continued)

Return to Section

Section TOC

Return to Master

Master TOC

To further check the drive motor:

12.Remove input power (115VAC) from the LN-8.

13.Locate and remove leads #539 and #541 from the control board, see Figure F.5.

14.Locate and remove leads #626 and #627 from the relay board.

15.Using the ohmmeter, measure the resistances per Table F.3.

16.If the motor resistance test is good, proceed to the Motor Applied Voltage Test.

3.Apply field voltage first (leads #626 and #627) to the motor. Then slowly apply the armature voltage at leads #539 and #541.

4.The motor should run and the speed should vary with changes to the armature voltage.

5.If the motor does NOT run and change speed correctly, the motor or gear box may be faulty.

6.To stop the motor, remove the armature voltage first, leads #539 and #541.

Return to

Return to

 

AFTER TESTING

MOTOR APPLIED

1. Replace motor leads.

VOLTAGE TEST

 

Section TOC

Master TOC

1.Carefully connect the isolated 120VDC supply (supply turned off) to motor leads #626 and #627, see

Figure F.5.

2.Carefully connect the variable 0 to 120VDC supply (supply turned off) to motor leads #539 and #541.

2.Install the screws that secure the left side cover assembly.

3.If disengaged, engage the drive rolls.

4.If removed, feed the electrode back into the wire drive unit.

Return to

Return to Section TOC

Return to

Return to Master TOC

TABLE F.3 – DRIVE MOTOR TEST POINTS

TEST POINTS

RESISTANCE

DC VOLTAGE

 

 

 

Lead #539 to #541

3 to 5 ohms

0 to 90VDC

Armature

 

 

 

 

 

Lead #626 to #627

750 to 950 ohms

90 to 120VDC

Field Winding

 

 

 

 

 

All leads to

500,000 ohms

N/A

motor shell

min.

 

 

 

 

LN-8

Page 73
Image 73