Lincoln Electric SVM132-A service manual Trigger Transformer Test, Test Description

Models: SVM132-A

1 99
Download 99 pages 19.61 Kb
Page 62
Image 62

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-12

TROUBLESHOOTING AND REPAIR

F-12

 

 

 

 

 

TRIGGER TRANSFORMER TEST

WARNING

Service and repair should be performed only by Lincoln Electric factory trained per- sonnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precau- tions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed.

Call (800) 833-9353 (WELD).

_____________________________________________________________

TEST DESCRIPTION

This test will aid the technician in determining if the Trigger Transformer is functioning properly.

This procedure takes approximately 8 minutes to perform.

MATERIALS NEEDED

115 VAC power supply 5/16 in. nutdriver Volt-Ohmmeter (Multimeter)

LN-8

Page 62
Image 62
Lincoln Electric SVM132-A service manual Trigger Transformer Test, Test Description