F-13

TROUBLESHOOTING AND REPAIR

F-13

 

 

 

 

 

TRIGGER TRANSFORMER TEST (continued)

FIGURE F.2 – TRIGGER TRANSFORMER TEST POINTS

6 5 4

RED

3 2 1

BLACK BLACK

RELAY

BOARD

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the LN-8.

2.Using the 5/16 in. nutdriver, remove the screws holding the left side cover assembly.

3.Disconnect the Molex plug from the under-side of the relay board. See Figure F.2.

4.Apply power (115VAC) to the black primary transformer leads, pins 2 and 3.

5.Using the voltmeter, check for approximately 24VAC at the red secondary leads, pins 1 and 4.

6.If 115VAC is applied to the black primary leads (2 and 3) and the secondary voltage (red leads 1 and 4) is missing or low, the trig- ger transformer may be faulty. Replace.

7.Reconnect the Molex plug to the underside of the relay board.

8.Install the screws that secure the left side cover assembly.