Lincoln Electric SVM132-A service manual Trigger Transformer Test

Models: SVM132-A

1 99
Download 99 pages 19.61 Kb
Page 63
Image 63

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-13

TROUBLESHOOTING AND REPAIR

F-13

 

 

 

 

 

TRIGGER TRANSFORMER TEST (continued)

FIGURE F.2 – TRIGGER TRANSFORMER TEST POINTS

6 5 4

RED

3 2 1

BLACK BLACK

RELAY

BOARD

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the LN-8.

2.Using the 5/16 in. nutdriver, remove the screws holding the left side cover assembly.

3.Disconnect the Molex plug from the under-side of the relay board. See Figure F.2.

4.Apply power (115VAC) to the black primary transformer leads, pins 2 and 3.

5.Using the voltmeter, check for approximately 24VAC at the red secondary leads, pins 1 and 4.

6.If 115VAC is applied to the black primary leads (2 and 3) and the secondary voltage (red leads 1 and 4) is missing or low, the trig- ger transformer may be faulty. Replace.

7.Reconnect the Molex plug to the underside of the relay board.

8.Install the screws that secure the left side cover assembly.

Return to Section TOC

Return to Master TOC

LN-8

Page 63
Image 63
Lincoln Electric SVM132-A service manual Trigger Transformer Test