F-7

 

TROUBLESHOOTING AND REPAIR

F-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS (Continued)

 

 

 

 

 

 

 

 

 

 

 

The wire feed speed cannot be

1.

If the LN-8 is being used for sub-

1.

Check for loose connections

 

 

 

controlled. The motor runs and

 

merged arc welding with the vari-

 

between the speed control, the

 

 

 

feeds wire but the speed cannot

 

able voltage board switch in the

 

control board, and the variable

 

 

 

be changed regardless of control

 

VV position, change it to the CV

 

voltage board. See wiring

 

 

 

setting.

 

 

position. If proper motor speed

 

diagram.

 

 

 

 

 

 

 

control returns, the variable volt-

 

 

 

 

 

 

 

 

 

age board may be faulty.

2.

Check the speed control rheostat

 

 

 

 

 

 

 

 

for proper operation. Normal

 

 

 

 

 

 

 

 

 

resistance is 5000 ohms.

 

 

 

 

 

 

 

 

3.

Perform the Drive Motor Test.

 

 

 

 

 

 

 

4.

The control board may be faulty.

 

 

 

 

 

 

 

 

 

The wire feed “coasts” when the

1.

Make sure the gun trigger is not

1.

Perform the 1CR Relay Test.

 

 

gun trigger is released.

 

 

“sticking”.

 

 

 

 

 

 

 

 

 

 

 

 

 

The wire feeds normally and welds

1.

Check or replace the solenoid.

1.

With the gun trigger activated,

 

 

 

but the solenoid is not operating.

 

 

 

check for the presence of

 

 

 

 

 

 

 

 

 

115VAC at terminals 32A and 7.

 

 

 

 

 

 

 

 

If the proper voltage is present,

 

 

 

 

 

 

 

 

the solenoid may be faulty. If the

 

 

 

 

 

 

 

 

correct voltage (115VAC) is NOT

 

 

 

 

 

 

 

 

present, the relay board may be

 

 

 

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

 

 

 

When the gun trigger is activated

1.

Check wire feed direction switch

1.

The 1CR relay may be faulty.

 

 

 

the wire “backs up” instead of feed-

 

for proper direction and operation.

 

Check or replace.

 

 

 

ing forward.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-800-833-9353.