F-68

F-68

TROUBLESHOOTING & REPAIR

INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)

7.Carefully remove the input rectifier bridge.

8.When installing a new input rectifier apply a thin coating of Penetrox A-13 Heat Sink Compound (Lincoln E2529) to the mating surfaces. Torque the mounting cap screws and nuts to 44 in-lbs.

9.Reconnect the 10 leads to the correct ter- minals and torque the phillips head screws to 31 in-lbs.

10.Apply Essex DC-4-8 Insulating Com- pound to all six screw heads and termi- nals. The heavy input lead terminals should be against the rectifier terminals.