When received directly from the factory, the machines are internally connected for 230 VAC. Reconnection will be necessary if a higher input voltage is used. To reconnect the Pro-Cut to 460 VAC or to connect back to 230 VAC, follow the directions as outlined below. Follow this procedure ONLY while the Pro-Cut is dis- connected from the input power.

CAUTION

Failure to follow these instructions can cause immedi- ate failure of components in the welder.

FIGURE A.2 – RECONNECTION DIAGRAM

RECONNECT PROCEDURE

 

WARNING

 

• Disconnect input power before

 

inspecting or servicing machine.

 

• Do not operate with wraparound

 

removed.

ELECTRIC

• Do not touch electrically live parts.

SHOCK

• Only qualified persons should install,

CAN KILL

use, or service this equipment.

1.BE SURE POWER SWITCH IS OFF.

2.CONNECT LEAD 'A' TO DESIRED INPUT VOLTAGE RANGE. 440 - 460V

1.

Open the access door on the back of the machine.

 

Connection instructions are also included on the

 

inside of the door.

2.

For 230: Position the large switch to 200-230. See

380 - 415V

220 - 230V

200 - 208V

'A'

Figure A.2.

For 460: Position the large switch to 380-460. See

Figure A-2.

3. Move the “A” lead to the appropriate terminal.

3.POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.

VOLTAGE = 380 - 460V