INSTALLATION
Return to Master TOC
RECONNECT PROCEDURE
When received directly from the factory, the machines are internally connected for 230 VAC. Reconnection will be necessary if a higher input voltage is used. To reconnect the
CAUTION
Failure to follow these instructions can cause immedi- ate failure of components in the welder.
FIGURE A.2 – RECONNECTION DIAGRAM
RECONNECT PROCEDURE
| WARNING |
| • Disconnect input power before |
| inspecting or servicing machine. |
| • Do not operate with wraparound |
| removed. |
ELECTRIC | • Do not touch electrically live parts. |
SHOCK | • Only qualified persons should install, |
CAN KILL | use, or service this equipment. |
1.BE SURE POWER SWITCH IS OFF.
2.CONNECT LEAD 'A' TO DESIRED INPUT VOLTAGE RANGE. 440 - 460V
1. | Open the access door on the back of the machine. |
| Connection instructions are also included on the |
| inside of the door. |
2. | For 230: Position the large switch to |
380 - 415V
220 - 230V
200 - 208V
'A'
Figure A.2. |
For 460: Position the large switch to |
Figure |
3. Move the “A” lead to the appropriate terminal. |
3.POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.
VOLTAGE = 380 - 460V
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
VOLTAGE = 200 - 230V