TROUBLESHOOTING & REPAIR

INPUT RECTIFIER TEST (continued)

Return to

TEST PROCEDURE

1.Remove main input power to the machine.

2.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

3.Locate the input rectifier (D1) and lead loca- tions. See Figure F.2.

4.With the phillips head screw driver, remove leads #207, 207A and #209 from the rectifi- er.

5.Use the analog ohmmeter to perform the tests detailed in Table F.1. See the Wiring Diagram.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

FIGURE F.2 – INPUT RECTIFIER AND LEADS

#207 (-)#207A

C

B

A

#209 (+)