OPERATION
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
CONTROLS AND SETTINGS
FIGURE B.2 - CASE FRONT CONTROLS
9 8 7
6
XXXX XXXX XXXX XXXX
5
1
OFF
2
4
3
1.OUTPUT CURRENT CONTROL KNOB
2.TORCH CONNECTOR
3.WORK CABLE
4.INPUT POWER SWITCH
5.GAS REGULATOR KNOB
6.GAS REGULATOR GAUGE
7.GAS PURGE BUTTON
8.RESET BUTTON
9.STATUS (DISPLAY) BOARD INDICATORS
1.OUTPUT CURRENT CONTROL KNOB - Adjusts the amount of cutting current applied. Affects cut- ting speed, dross formation, cut width, heat zone and travel speed.
2.TORCH CONNECTOR -
3.WORK CABLE - Provides clamp and cable con- nection to workpiece.
4.ON/OFF POWER SWITCH - Turns machine on or off.
5.GAS REGULATOR KNOB - Adjusts compressed gas pressure delivered to the torch. Length of torch hose is an adjustment factor. Optimum set- ting is
6.GAS REGULATOR GAUGE - Provides gas pressure reading as set by the gas regulator knob.
7.GAS PURGE BUTTON - Used to check or set gas pressure. Push in and hold to check pressure, then continue to hold to set the pressure. Shuts off gas when released.
8.RESET BUTTON - Used to reset the machine fol- lowing a safety circuit trip.
9.STATUS (DISPLAY) BOARD INDICATORS - Four lights indicating Power, Gas Low, Thermal and Safety.
PILOT ARC CONSIDERATIONS
The
When the pilot arc is started, a slight impulse will be felt in the torch handle. This occurrence is normal and is the mechanism which starts the plasma arc. This impulse can also be used to help troubleshoot a "no start" condition.
CUTTING OPERATION
When preparing to cut or gouge, position the machine as close to the work as possible. Make sure you have all materials needed to complete the job and have taken all safety precautions. It is important to follow these operating steps each time you use the machine.
•Turn the machine's ON/OFF POWER SWITCH to the OFF position.
•Connect the air supply to the machine.
•Turn the main power and the machine power switch on.
-The fan should start.
-The
-If the "SAFETY" status indicator is lit, push the "Reset" button. If there is no problem, the status indicator will go off. If there is a problem, refer to "STATUS INDICATOR" in this section.
•Be sure that the work lead is clamped to the work- piece before cutting.
•Set the output current control knob for maximum current for high cutting speed and less dross forma- tion per Figure B.1. Reduce the current, if desired, to reduce the kerf (cut) width, heat affected zone or travel speed as required.
•
-Adjust the gas regulator for 70 PSI for 25 foot (7.62m) torches or 75 PSI for 50 foot (15.24m) torches.
-Release the Purge button.