| TROUBLESHOOTING & REPAIR | |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
|
| |||
|
|
|
|
|
|
|
|
| CUTTING PROBLEMS |
|
|
|
|
|
|
The pilot arc is normal, but the arc | 1. Make sure the operating proce- | 1. | Check the lead connections X2, | ||||
will not transfer to the workpiece. | dure is correct for the process. |
| X4 and B21 at the output board. | ||||
| See the Operation section of | 2. | Check | the | output | control | |
| this manual. | ||||||
|
| potentiometer (R1). | Normal | ||||
|
|
| |||||
| 2. Make sure the work clamp is |
| resistance is | 10 ohms. | Also | ||
| connected tightly to the work- |
| check the associated leads for | ||||
| piece. |
| loose or faulty connections to | ||||
| 3. The workpiece must be electri- |
| the display | board. See | the | ||
|
| Wiring Diagram. |
|
| |||
| cally conductive material. |
|
|
| |||
|
|
|
|
|
|
| |
|
| 3. | Check leads #216, #218 and | ||||
|
|
| #219 between the | display | |||
|
|
| board and the control board. | ||||
|
|
| Check for loose or faulty con- | ||||
|
|
| nections. | See the | Wiring | ||
|
|
| Diagram. |
|
|
|
|
|
| 4. | The control board may be | ||||
|
|
| faulty. Replace. |
|
| ||
|
| 5. | The output board may be faulty. | ||||
|
|
| Perform | the | Output | Board | |
|
|
| Resistance Test. |
|
| ||
|
| 6. | The display board may be | ||||
|
|
| faulty. Replace. |
|
| ||
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call