Return to Section TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
PRIMARY POWER BOARD RESISTANCE TEST AND
CAPACITOR VOLTAGE TEST (continued)
FIGURE F.3 – PRIMARY POWER BOARD REMOVAL
Return to Section TOC
Return to Master TOC
PRIMARY POWER
BOARD WITH
INPUT FILTER
CAPACITORS
CAPACITOR (C2)
TERMINALS
| + |
|
207 | 202 |
|
| 204 | |
|
| ] |
201 |
| |
|
| G3172 |
205 | 208 | |
|
|
206 203
+
CAPACITOR (C1) TERMINALS
Return to Section TOC
Return to Master TOC
TEST PROCEDURE
1.Remove main input power to the
2.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.
3.Locate the primary power board and asso- ciated lead locations. See Figure F.3.
4.Carefully remove the main transformer pri- mary leads #201, #204, #205 and #208 from the power board.
5.Use the analog ohmmeter to perform the test outlined in Table F.2.