to Section TOC
to Master TOC
TROUBLESHOOTING & REPAIR
OUTPUT POWER BOARD RESISTANCE TEST (continued)
FIGURE F.4 – OUTPUT POWER BOARD LEAD LOCATIONS
Return
Return
X4
(B11)
B21
TOC
TOC
G3326 - [ ]
X2 |
(B12) |
B1
B2
D30 | Test Point |
J33
x40
TOC
TOC
J32
TEST PROCEDURE
1.Remove input power to the
2.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.
3.Remove the torch assembly from the machine.
4.Remove leads X4, X2, B21, X20, X40 and plugs J33 and J32 from the output power board. See Figure F.4.
5.Using the analog ohmmeter, perform the resistance checks per Table F.4.
Return to Section TOC
Return to Master TOC