to Section TOC
to Master TOC
TROUBLESHOOTING & REPAIR
PRIMARY POWER BOARD RESISTANCE TEST AND
CAPACITOR VOLTAGE TEST (continued)
Return
Return to Section TOC
Return to Section TOC
CAPACITOR VOLTAGE TEST
This test will help the technician to determine if the input filter capacitors are being charged equally to the correct voltage levels.
NOTE: This test should only be conducted with the
TEST PROCEDURE
1.Remove main input power to the
2.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.
3.Locate and familiarize yourself with the capacitor test locations on the primary power board. See Figure F.3.
4.The following tests will be performed with the input power applied to the
BE CAREFUL. ALWAYS REMOVE THE INPUT POWER AND PERFORM THE INPUT FILTER CAPACITOR DISCHARGE PROCEDURE BEFORE TOUCHING ANY MACHINE COMPONENT.
WARNING
ELECTRIC SHOCK can kill.
• Have an electrician install and service this equipment.
•Turn the input power off at the fuse box before working on equipment.
•Do not touch electrically hot parts.
5.Apply the correct input power† and turn ON the
†NOTE: This test should only be conducted with the
Return to Section TOC
Return to Master TOC