(T2) AUXILIARY TRANSFORMER TEST (continued)

TABLE F.6 - J21 AND J22 (6 Pin) VOLTAGES

TEST POINT

 

TEST POINT

 

EXPECTED VOLTAGE

H1 (1J22)

 

H2 (4J22)

 

200 - 208VAC

H1 (1J22)

 

H4 (3J22)

 

380 - 415VAC

H1 (1J22)

 

H5 (6J22)

 

440 - 460VAC

Brown (8J21)

 

Brown (3J21)

 

12VAC

Red (2J21)

 

Red (6J21)

 

24VAC

Blue (9J21)

 

White (5J21)

 

18VAC

Blue (4J21)

 

White (5J21)

 

18VAC

 

 

 

 

 

 

J21 AND J22 (8 Pin) VOLTAGES

 

TEST POINT

TEST POINT

EXPECTED VOLTAGE

H1 (1J22)

H2 (5J22)

200 - 208VAC

H1 (1J22)

H4 (7J22)

380 - 415VAC

H1 (1J22)

H5 (8J22)

440 - 460VAC

H1 (1J22)

H6 (4J22)

560 - 600VAC

Brown (8J21)

Brown (3J21)

12VAC

Red (2J21)

Red (6J21)

24VAC

Blue (9J21)

White (5J21)

18VAC

Blue (4J21)

White (5J21)

18VAC

 

 

 

Return to Section TOC

Return to Master TOC

7.If the correct test voltages are present, the auxiliary transformer is good.

8.If any of the voltages are missing or very low with the proper primary voltage applied, the auxiliary transformer may be faulty.

9.If the auxiliary transformer tests good but it does not function when connected to the Pro-Cut 55, check the harness wiring to the auxiliary transformer. See the Wiring Diagram.

10.When finished with the test, replace plugs 21 and 22 and the case wraparound.

NOTE: There should not be continuity between the isolated windings. With the input power removed from the transformer, check the windings using the table below.

Return to Section TOC

Return to Master TOC

TEST POINT

TEST POINT

EXPECTED RESISTANCE

H1

Brown Lead

Greater than 100 K ohms

H1

Red Lead

Greater than 100 K ohms

H1

Blue/White Leads

Greater than 100 K ohms

Brown Leads

Red Leads

Greater than 100 K ohms

Brown Leads

Blue/White Leads

Greater than 100 K ohms

Red Leads

Blue/White Leads

Greater than 100 K ohms

 

 

 

PRO-CUT 55