Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-2

A-2

INSTALLATION

TECHNICAL SPECIFICATIONS - PRO-CUT 55

 

 

INPUT RATINGS

 

 

Single Phase Input

 

Input Currents

 

Rated Output Amps

Voltage and Hertz

 

 

 

 

 

208/1/60

 

60

 

 

55

230/1/60

 

55

 

 

55

460/1/60

 

30

 

 

55

208/1/60

 

44

 

 

40

230/1/60

 

40

 

 

40

460/1/60

 

23

 

 

40

 

 

 

 

 

Three Phase Input

 

Input Currents

 

Rated Output Amps

Voltage and Hertz

 

 

 

 

 

208/3/60

 

31

 

 

55

230/3/60

 

28

 

 

55

460/3/60

 

17

 

 

55

208/3/60

 

23

 

 

40

230/3/60

 

21

 

 

40

460/3/60

 

15

 

 

40

 

 

 

 

 

 

IDLE CURRENT AND WATTS

230/1/60

 

0.42 Amps

 

98 Watts

 

 

 

 

 

 

 

 

RATED

OUTPUT

 

 

Duty Cycle

 

 

 

Rated Output Amps

50%

 

 

 

55

100%

 

 

 

40

 

 

 

 

 

 

 

 

OUTPUT

 

 

Current Range

 

Open Circuit Voltage

 

Pilot Current

25 - 55 Amps

 

335VDC Maximum

 

18 Amps @ 100%

 

 

 

 

 

Duty Cycle

 

 

 

 

 

 

PRO-CUT 55

Page 7