INSTALLATION
TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 55
GAS REQUIREMENTS
Required Gas Flow Rate | Required Gas Inlet Pressure | |||
70 PSI @ 360 SCHF | 80 to 150 PSI | |||
(4.8 Bar. @ 10160 LHR) | (5.4 Bar. to 10.2 Bar.) | |||
(6 CFM) |
|
|
|
|
|
| |||
RECOMMENDED INPUT WIRE AND FUSE SIZES | ||||
For all plasma cutting applications based on U.S. National Electrical Code | ||||
| Ambient Temperature 30°C or Less |
|
| |
AC Input Voltage | Fuse (Super Lag) | Type 75°C |
|
|
at | Circuit Breaker | Copper Wire in Conduit AWG | ||
60 Hertz | (Delay Type) | (IEC) Sizes |
|
|
|
|
|
|
|
|
| 2 Input Supply Wires | 1 Ground Wire | |
230VAC Single Phase | 70 Amps | #8 (8.4mm2) | #10 (5.3mm2) | |
460VAC Single Phase | 40 Amps | #8 (8.4mm2) | #10 (.3mm2) | |
230VAC Three Phase | 40 Amps | #10 (5.3mm2) | #10 (5.3mm2) | |
460VAC Three Phase | 20 Amps | #10 (5.3mm2) | #10 (5.3mm2) |
| PHYSICAL | DIMENSIONS |
|
Height | Width | Depth | Weight with |
|
|
| Torch Cable |
12.6 Inches | 11.0 Inches | 26.0 Inches | 70 lbs. (32 kg.) |
320 mm | 280 mm | 660 mm | (25 ft. cable) |
|
|
| 85 lbs. (39 kg.) |
|
|
| (50 ft. cable) |
|
|
|
|