HARDWIRED LOOP WIRING

HARDWIRED LOOP WIRING

The DUAL 824 supports up to eight normally open/closed hardwired loops each with 2.2K end-of-line resistor supervision.

Each hardwired loop that is wired and programmed uses one sensor location.

Each hardwired loop can be programmed to any sensor number.

Each hardwired loop can be programmed as any sensor type, including arm/disarm toggle.

Four COM terminals are shared as loop returns for the eight loops.

Each hardwired loop has a 400 millisecond response time.

NOTE: For UL installations, use UL Listed cable for all hardwired loop wiring.

1.Route wiring from the Control Panel to each hardwired switch contact, sensor, or device. Route the wires through the wiring slot or through a knockout for conduit wiring.

NOTE: Maximum recommended hardwired loop length is 500 feet (250' out, and 250' back) for each loop. Maximum loop resistance (excluding the EOL resistor) is 100 ohms.

2.Connect the loop wires to LOOP # and COM terminals. For powered devices connect power wires to +12 VDC and any COM terminal.

3.On the sensor end, connect each normally closed sensor in series with the loop wires. Connect each normally open sensor in parallel with the loop wires. See wiring figure.

4.After the last sensor on the loop, connect a 2.2K end-of-line resistor across the loop.

NOTE: Before the hardwired loops will function, they will need to be programmed. This will be covered in the Basic Control Panel Programming section of this manual.

RUN LOOP WIRING BETWEEN THE CONTROL PANEL AND THE REMOTE

HARDWIRED SENSORS

4-CONDUCTOR

FOR HARDWIRED INFRAREDS MAIN TERMINAL BLOCKARM/DISARM KEY STATION WIRINGManual backgroundManual backgroundManual background

2-CONDUCTOR FOR MAGNETIC

CONTACTS

RUN 4-CONDUCTOR WIRE

Manual backgroundManual backgroundManual background TO POWERED DEVICES

RUN 2-CONDUCTOR WIRE

TO DEVICES NOT POWERED

FROM THE CONTROL PANEL

MAIN TERMINAL BLOCK

LOOP

COM LOOP

LOOP

COM LOOP

COM LOOP

H/A

H/A

RLY

RLY

RLY

+12

1

2

3

4

8

-

+

COM

N/C

N/O

VDC

NORMALLY OPEN

SWITCHES (CONTACTS)

2.2K END-OF-LINE RESISTOR FOR EACH LOOP USED

NORMALLY CLOSED

SWITCHES (CONTACTS)

USE +12 VDC AND ANY COM TERMINAL TO POWER EXTERNAL DEVICES (1 AMP MAX.)

CONNECT EACH HARDWIRED INPUT TO A LOOP AND COM TERMINAL

FOR POWERED DEVICES, WIRE POWER LEADS TO +12 VDC AND ANY COMMON TERMINAL (OBSERVE POLARITY)

ARM/DISARM KEY STATION WIRING

Any of the hardwired loops can be used with a momentary keyswitch to arm and disarm the system.

1.Connect the loop as shown to the keyswitch and end-of-line resistor.

2.Connect an LED indicator from the switch plate to the H/A- and H/A+ terminals.

3.When programming the system, set the loop sensor function to “Type 9, Arm/Disarm Toggle” and set the Automation output to “Active while Armed”.

MAIN TERMINAL BLOCK

LOOP

COM LOOP

LOOP

COM LOOP

 

COM LOOP

H/A

H/A

RLY

RLY

RLY

1

 

2

3

4

8

-

 

+

 

COM

N/C

N/O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROGRAM LOOP FOR

 

PROGRAM AUTOMATION

ARM/DISARM TOGGLE

KEYSTATION

OUTPUT FOR "ACTIVE

(SENSOR TYPE 9)

WHILE ARMED"

LED WILL LIGHT

 

 

WHEN SYSTEM

LED

 

IS ARMED

 

 

 

 

470 OHM

 

 

 

NORMALLY CLOSED,

 

2.2K OHM

SPRING RETURN, KEYSWITCH

10