Linear DUAL 824 manual Advanced Programming, Setup Mode, Control Panel Programming Table

Models: DUAL 824

1 48
Download 48 pages 4.08 Kb
Page 31
Image 31
13.ADVANCED PROGRAMMING

13.ADVANCED PROGRAMMING

To perform any of the advanced programming steps, the system must be in the Setup Mode.

Each programming function is performed with similar keystrokes. After the system is in Setup Mode, enter the programming step or sensor number and press HOME, then enter the new value and press AWAY. For reference, follow the figures next to the programming steps.

If the new value is accepted, a “bing” will sound. If the new value is not accepted, a “double buzz” will sound.

ENTERS PROGRAM STEP OR

SENSOR NUMBER TO MODIFY

ENTERS PROGRAM STEP OR STORES NEW VALUE

SETUP MODE

1.Start with the system in Test Mode (Setup Mode cannot be reached from any other mode).

2.From Test Mode, enter the master user code then press TEST.

NOTE: Only the master user code can be used to put the system into the Setup Mode. The restricted user codes cannot access Setup Mode, only Code Mode.

A “Gong” and fi ve “Beeps” will sound, signaling that the system is in Setup Mode.

3.After programming changes are complete, press the OFF key for three seconds to exit Setup Mode.

NOTE: If the system is left unattended in Setup Mode, it will automatically switch back to Off Mode after three minutes.

CONTROL PANEL PROGRAMMING OPTIONS

STEP #

PROGRAMMING FUNCTIONS

 

POSSIBLE VALUES

FACTORY VALUE

INSTALLATION VALUE

25

ENTRY DELAY

20-255 SECONDS

30

 

 

 

 

 

 

26

EXIT DELAY

20-255 SECONDS

60

 

 

 

 

 

 

30

BURGLARY SIREN TIME

1-30 MINUTES

5

 

 

 

 

 

 

31

EMERGENCY SIREN TIME

1-30 MINUTES

5

 

 

 

 

 

 

32

FIRE SIREN TIME

1-30 MINUTES

5

 

 

 

 

 

 

40

AUTOMATION OUTPUT TIME

0-2500 SECONDS (0 = TOGGLE ON/OFF)

0

 

 

 

 

 

 

 

50

REMOTE ARMING MODE

2

= HOME MODE; 3 = AWAY MODE

3

 

 

 

 

 

 

 

51

REMOTE DISARMING MODE

0

= OFF MODE; 1 = CHIME MODE

0

 

 

 

 

 

 

 

61

ENTRY DELAY BEEPS

0

= OFF; 1 = ON

1

 

 

 

 

 

 

 

62

EXIT DELAY BEEPS

0

= OFF; 1 = ON

1

 

 

 

 

 

 

 

63

SILENT BURGLARY ALARM

0

= AUDIBLE; 1 = SILENT

0

 

 

 

 

 

 

 

64

SILENT EMERGENCY ALARM

0

= AUDIBLE; 1 = SILENT

0

 

 

 

 

 

 

 

65

QUICK ARMING

0

= OFF; 1 = ON

1

 

 

 

 

 

 

 

66

AUTO RESTORE

0

= OFF; 1 = ON

1

 

 

 

 

 

 

 

67

AUTO BYPASS

0

= OFF; 1 = ON

0

 

 

 

 

 

 

 

68

AUTOMATION MODE DURING ALARM

0

= FLASH (ENABLED BY FUNCTION 72)

0

 

1

= STEADY (ENABLED BY FUNCTION 72)

 

 

 

 

 

69

AUTOMATION BING TOME

0

= NO BINGS

1

 

1

= BINGS

 

 

 

 

 

70

REMOTE ARM/DISARM CHIRP

0

= NO CHIRPS

1

 

1

= CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED)

 

 

 

 

 

71

AUTOMATION FLASHES AFTER ALARM

0

= STANDARD

0

 

1

= FLASHING AFTER ALARM

 

 

 

 

 

 

 

0

= STANDARD

 

 

72

AUTOMATION ACTIVE DURING ALARM

1

= AUTOMATION ACTIVE DURING ALARM

0

 

 

 

(FLASH OR STEADY PROGRAMMED BY FUNCTION 68)

 

 

73

AUTOMATION ON WHILE ARMED

0

= STANDARD

0

 

1

= ON WHILE ARMED

 

 

 

 

 

74

AUTOMATION ON DURING EXIT/ENTRY

0

= STANDARD

0

 

1

= ON DURING EXIT/ENTRY DELAY

 

 

 

 

 

75

AUTOMATION POLARITY

0

= + WHEN OFF; 1 = + WHEN ON

1

 

 

 

 

 

 

87

REMOTE ACCESS PASSWORD

6 DIGITS

987654

 

92

DURESS CODE

1-5 DIGITS

REMOVED

 

 

 

 

 

 

93

RESTRICTED USER CODE #1

1-5 DIGITS

REMOVED

 

 

 

 

 

 

94

RESTRICTED USER CODE #2

1-5 DIGITS

REMOVED

 

 

 

 

 

 

95

RESTRICTED USER CODE #3

1-5 DIGITS

REMOVED

 

 

 

 

 

 

96

RESTRICTED USER CODE #4

1-5 DIGITS

REMOVED

 

 

 

 

 

 

97

RESTRICTED USER CODE #5

1-5 DIGITS

REMOVED

 

 

 

 

 

 

98

PAGE ALERT USER CODE

1-5 DIGITS

REMOVED

 

 

 

 

 

 

99

MASTER USER CODE

1-5 DIGITS

1234

 

 

 

 

 

 

 

Control Panel Programming Table

29

Page 31
Image 31
Linear DUAL 824 manual Advanced Programming, Setup Mode, Control Panel Programming Table, Stores New Value