FIRE SIREN TIME

✦The factory-set fire siren time is five minutes (UL installation maximum).

STEP #32 The fire siren time can be adjusted from one to 30 minutes using this step.

PROGRAMMING STEP #32

ENTERS STEP NUMBER

TIME IN MINUTES 1 - 30

STORES VALUE - 1 BING

AUTOMATION OUTPUT TIME

✦The factory setting causes the Automation Output to toggle between on and off with each activation.

STEP #40 The Automation Output can be programmed to turn on, then automatically turn off after one to 2500 seconds (42 minutes), or toggle on & off, using this step.

PROGRAMMING STEP #40

ENTERS STEP NUMBER

TIME IN SECONDS 1 - 2500 0 = TOGGLE ON & OFF

STORES VALUE - 1 BING

REMOTE CONTROL & HARDWIRE ARMING LEVEL

✦The factory setting causes the portable remote controls to arm to the Away Mode.

STEP #50 The portable remote controls can be changed to

arm to the Home Mode using this step.

✎NOTE: Changing this setting will affect all the portable remote controls used with the system and all hardwired loops programmed as arm/disarm (sensor Function #9) key stations.

PROGRAMMING STEP #50

ENTERS STEP NUMBER

2 FOR HOME MODE

3 FOR AWAY MODE

STORES VALUE - 1 BING

REMOTE CONTROL & HARDWIRE DISARMING LEVEL

✦The factory setting causes the portable remote controls to disarm to the Off Mode.

STEP #51 The remote controls can be changed to disarm to the Chime Mode using this step.

✎NOTE: Changing this setting will affect all the portable remote controls used with the system and all hardwired loops programmed as arm/disarm (sensor Function #9) key stations.

PROGRAMMING STEP #51

ENTERS STEP NUMBER

0 FOR OFF MODE

1 FOR CHIME MODE

STORES VALUE - 1 BING

ENTRY DELAY BEEPS

✦The factory setting causes the keypad(s) to beep during Entry Delays.

STEP #61 The Entry Delay beeps can be silenced using this step.

✦With the Entry Delay beeps off, the keypad(s) will be silent after a delayed sensor is triggered until the Entry Delay expires, then the alarm siren will sound.

PROGRAMMING STEP #61

ENTERS STEP NUMBER

0 FOR ENTRY BEEPS OFF

1 FOR ENTRY BEEPS ON

STORES VALUE - 1 BING

EXIT DELAY BEEPS

✦The factory setting causes the keypad(s) to beep during Exit Delays.

STEP #62 The Exit Delay beeps can be silenced using this step.

✦With the Exit Delay beeps off, the keypad(s) will be silent after arming to the Away Mode until the Exit Delay expires, then a single “Gong” tone will sound.

PROGRAMMING STEP #62

ENTERS STEP NUMBER

0 FOR EXIT BEEPS OFF

1 FOR EXIT BEEPS ON

STORES VALUE - 1 BING