REPORT CONTROL PANEL TROUBLE
✦The factory setting does not report Control Panel trouble events to the Central Station.
STEP #108 The communicator can be programmed to report Control Panel trouble events using this step. These include all conditions that light the keypad(s) BATTERIES or TROUBLE indicator. It also includes low Control Panel backup battery.
PROGRAMMING STEP #108
ENTERS STEP NUMBER
0 FOR NO CONSOLE TROUBLE
1 FOR CONSOLE TROUBLE
STORES VALUE - 1 BING
REPORT FORCE ARMING
✦The factory setting does not send force arming reports.
STEP #110 The communicator can be programmed to report force arming anytime the Control Panel is armed with one or more bypassed sensors using this step.
✦The factory set reporting code for force arming is “65” (Code 574 with Ademco).
✎NOTE: If force arming is enabled, and the Control Panel is force armed (armed with an open sensor) remotely by telephone, or with the
PROGRAMMING STEP #110
ENTERS STEP NUMBER
0 FOR NO FORCE ARMING RPTS.
1 FOR FORCE ARMING RPTS.
STORES VALUE - 1 BING
OPENING AND CLOSING REPORTS
✦The factory setting does not send opening and closing reports.
STEP #111 The communicator can be programmed to send an opening report when the system is disarmed, and a closing report when the system is armed for all users, or just the master user using this step.
✎NOTE 1: For commercial installations with retail traffic using opening and closing reports, it is recommended to disable quick arming to prevent customers from arming the system.
✎NOTE 2: The reporting codes are fixed for opening and closing. A unique code is reserved for the master user code and each of the five restricted user codes.
✎NOTE 3: Arming or disarming with the page alert user code dials the supervisory number, no opening or closing report is sent.
PROGRAMMING STEP #111
ENTERS STEP NUMBER
0 FOR NO OPEN/CLOSE REPORTS
1 FOR O/C RPTS. FOR ALL USERS
2 FOR O/C RPTS. FROM MASTER USER ONLY
STORES VALUE - 1 BING
POINT ID REPORTING
✦The factory setting enables Point ID and allows the communicator to send
STEP #113 Point ID can be disabled using this step. The Central Station will only receive general alarm and trouble reports.
PROGRAMMING STEP #113
ENTERS STEP NUMBER
0 FOR GENERAL REPORTS ONLY
1 FOR POINT ID REPORTING
STORES VALUE - 1 BING
41