AUTOMATION OUTPUT MODE DURING ALARM

 

 

 

 

The factory setting causes the Automation

PROGRAMMING STEP #68

 

Output to flash if it is programmed to activate

 

 

 

during or after an alarm.

 

 

 

NOTE: For the Automation Output to activate

ENTERS STEP NUMBER

 

during or after an alarm, that function must be

0 FOR FLASHING OUTPUT

 

enabled with Programming Step 71 or 72.

 

1 FOR STEADY OUTPUT

 

STEP #68 The output can be programmed to be a steady

 

STORES VALUE - 1 BING

 

output using this step.

 

 

 

 

 

 

 

 

 

AUTOMATION ACTIVATION TONE

 

 

 

The factory setting causes the keypad(s) to

PROGRAMMING STEP #69

 

sound a “Bing” when the Automation Output is

 

 

 

activated by pressing the

key, or when it's

 

 

triggered with a two-button remote control.

ENTERS STEP NUMBER

 

STEP #69 This sound can be silenced using this step.

0 FOR BING TONE OFF

 

 

 

 

 

 

1 FOR BING TONE ON

 

 

 

STORES VALUE - 1 BING

 

 

 

 

 

 

 

 

 

REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP

When arming with the portable remote control or with a hardwired loop programmed as arm/ disarm (sensor Function #9), the factory setting causes the keypad(s) to “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed.

STEP #70 These chirps can be silenced using this step.

NOTE: If these chirps are silenced, it is recommended to program the Automation Output to be active when the system is armed, so a light can be triggered displaying the arming status of the system.

PROGRAMMING STEP #70

ENTERS STEP NUMBER

0 FOR CHIRPS OFF

1 FOR CHIRPS ON

STORES VALUE - 1 BING

AUTOMATION OUTPUT ON DURING AND AFTER ALARM

The factory setting causes the Control Panel's

Automation Output to activate when pressing the key, or when it's triggered with a two-button remote control.

STEP #71 The Control Panel can be programmed to activate the Automation Output during and after any alarms as well as when normally triggered using this step.

NOTE: The output will continue until the flashing sensor status lights are cleared.

PROGRAMMING STEP #71

ENTERS STEP NUMBER

0 FOR STANDARD TRIGGER

1 FOR OUTPUT DURING & AFTER ALARM

STORES VALUE - 1 BING

AUTOMATION OUTPUT ON DURING ALARM

The factory setting causes the Control Panel's

Automation Output to activate when pressing the key, or when it's triggered with a two-button remote control.

STEP #72 The Control Panel can be programmed to activate the Automation Output during alarms as well as when normally triggered using this step.

NOTE: The Automation Output can be programmed to flash or be steady during alarm, see Programming Step 68.

PROGRAMMING STEP #72

ENTERS STEP NUMBER

0 FOR STANDARD TRIGGER

1 FOR OUTPUT DURING ALARM

STORES VALUE - 1 BING