CALL LIMITER

CALL LIMITER

The factory setting for the call limiter is OFF. This allows the communicator to report burglary alarms, once for each sensor, as many times as they are triggered.

STEP #101 The Control Panel can be programmed to only allow five burglary reports total per arming period using this step.

NOTE: Sensors programmed for 24-hour functions (Emergency, Panic, Fire) always send a Central Station report and always sound the local siren regardless of the Call Limiter setting.

PROGRAMMING STEP #101

ENTERS STEP NUMBER

0 FOR OFF (UNLIMITED)

1 FOR ON (5 VIOLATIONS)

STORES VALUE - 1 BING

DIALING DELAY

The factory setting will cause the communicator to dial the Central Station instantly when an alarm or supervisory event occurs.

STEP #103 The communicator can be programmed to wait 30 seconds before dialing using this step. This gives the user time to disarm the system and prevent communications in the case of a subscriber generated false alarm.

PROGRAMMING STEP #103

ENTERS STEP NUMBER

0 FOR NO DELAY

1 FOR 30 SECOND DELAY

STORES VALUE - 1 BING

DIALING METHOD

The factory setting causes the communicator to dial using DTMF (dual-tone multi-frequency) tone dialing.

STEP #104 The communicator can be programmed to use pulse (rotary) dialing using this step. Use this option if the telephone line in the installation does not support tone dialing.

PROGRAMMING STEP #104

ENTERS STEP NUMBER

0 FOR TONE DIALING

1 FOR PULSE DIALING

STORES VALUE - 1 BING