Linear DUAL 824 manual Adding Additional User Codes, Removing Additional User Codes

Models: DUAL 824

1 48
Download 48 pages 4.08 Kb
Page 37
Image 37
ADDING ADDITIONAL USER CODES

ADDING ADDITIONAL USER CODES

The Control Panel can be programmed with five restricted user codes and one page alert user code.

The restricted user codes operate the system as usual, but cannot access Setup Mode.

The restricted user codes can access a special Code Mode that can be used to change or remove any of the five restricted user codes, the page alert user code, or the duress code.

The page alert user code dials the supervisory number (programmed for a pager) when it is used to arm or disarm the system.

A restricted user code is appropriate to give any user that should be restricted from programming the Control Panel.

NOTE: For maximum security, a 3-5 digit code is recommended.

WARNING: NEVER PROGRAM ANY RESTRICTED USER CODETHE SAME ASTHE MASTER USER CODE!

PROGRAMMING STEP #93-98

ENTERS STEP NUMBER

1-5 DIGIT ADDITIONAL USER CODE

(3-5 DIGITS RECOMMENDED)

STORES CODE - 1 BING

STEP

CODE FUNCTION

CODE ENTERED

STEP #93

RESTRICTED USER CODE #1

 

 

 

 

STEP #94

RESTRICTED USER CODE #2

 

 

 

 

STEP #95

RESTRICTED USER CODE #3

 

 

 

 

STEP #96

RESTRICTED USER CODE #4

 

 

 

 

STEP #97

RESTRICTED USER CODE #5

 

 

 

 

STEP #98

PAGE ALERT USER CODE

 

 

 

 

STEPS #93-98Create any additional user codes using these steps then log the codes in the boxes to the right.

REMOVING ADDITIONAL USER CODES

STEPS #93-98Any additional user code can be removed

 

ENTER FOR STEP #

from the Control Panel by entering the

93 = RESTRICTED CODE 1

appropriate step number and pressing TEST.

94 = RESTRICTED CODE 2

Because access to programming would be

95 = RESTRICTED CODE 3

96 = RESTRICTED CODE 4

impossible without a master user code, it cannot be

97 = RESTRICTED CODE 5

removed using these steps. The master user code

98 = PAGE ALERT USER CODE

can be changed using programming STEP #99.

 

NOTE: The master user code can be set to the

PROGRAMMING STEP #93-98

factory default using the Control Panel master

 

reset programming step, although all other system

 

programming will be reset to factory values and all

REMOVES CODE - 1 BING

sensors programmed will be erased.

 

CONTROL PANEL MASTER RESET

Master resetting the Control Panel will set all of the programming options back to the factory values. The master user code will be reset to 1234.

CAUTION: Master resetting the Control Panel will erase the user codes and remove all programmed sensors. All Control Panel and communicator programming values will be reset to the factory defaults.

1.Start with the system in Test Mode (Setup Mode cannot be reached from any other mode).

2.From Test Mode, enter the master user code then press TEST.

A “Gong” and fi ve “Beeps” will sound, signaling that the system is in Setup Mode.

3.Enter programming STEP #999 then press TEST.

4.Enter 999 again then press TEST again.

A “Bing” will sound to indicate the beginning of the reset process. This process will take up to 10 seconds while the memory is being reset.

The system will revert to the first time power- up condition and the new master user code will be 1234. Go to the “Basic Control Panel Programming” section of this manual to begin re- programming the system.

START IN TEST

MASTER USER CODE

ENTERS TEST MODE 1 GONG & 5 BEEPS

STEP #999

FOR MASTER

RESET

ENTERS STEP NUMBER

ENTER 999 TO OK

THE MASTER RESET

PRESS TEST, 1 BING SOUNDS,

WAIT ABOUT 10 SECONDS

DONE

USE THESE EXACT KEYSTROKES

TO PERFORM A MASTER RESET

35

Page 37
Image 37
Linear DUAL 824 manual Adding Additional User Codes, Removing Additional User Codes, Control Panel Master Reset