DXS-31 & DXS-32 DOOR/WINDOW SENSORS

The DXS-31 and DXS-32 sensors can be used

to monitor doors, windows, cabinets, crawl space

doors, gates, freezer doors, and many other

moving objects that could be used for intrusion or

need to be monitored.

A built-in magnetic switch triggers the sensor

when its magnet (mounted on the moving part

EXAMPLE INSTALLATIONS (WITH DXS-31 SHOWN)

LEFT OPENING DOOR

SLIDING WINDOW

TRANSMITTER

MOUNTED ON

DOOR JAMB MAGNET MOUNTED

ON WINDOW FRAME

(NOTE: SMALL END OF TRANSMITTER UP)

MAGNET MOUNTED

ON DOOR

TRANSMITTER

MOUNTED ON

WINDOW SILL

or the door or window) moves away from the

sensor.

The DXS-31 sensor can be wired to external

normally closed switches for remote triggering.

The DXS-31 sensor can connect directly to a

glass break detector.

SET SENSOR JUMPER

A jumper inside the door/window sensor selects instant or delayed response.

1A. If the sensor is going to be used on the primary entry/exit door make sure that the jumper is in the DELAY position.

1B. If the sensor is going to be used on a window or a door that is not going to be used to enter and exit the premises, set the jumper to the INSTANT position.

RIGHT OPENING DOOR

TRANSMITTER

MOUNTED ON

DOOR JAMB

(NOTE: SMALL END

OF TRANSMITTER DOWN)

MAGNET MOUNTED

ON DOOR

INSTANT/DELAY

ANTENNA

OPTION JUMPER

 

INPUT

MAGNET

ALIGNMENT

SELECT

MARK

JUMPER

 

TRANSMIT

 

INDICATOR

 

TEST

EXTERNAL

SWITCH

INPUT

 

 

TERMINALS

DOUBLE-HUNG

WINDOW

TRANSMITTER

MOUNTED ON

WINDOW FRAME

MAGNET

MOUNTED

ON WINDOW

SASH STILE

TWO TYPE 2032

BATTERIES

BATTERY

CLAMP

SCREW

BATTERY CLAMP

CHOOSE MOUNTING METHOD

2A. Apply double-stick tape (supplied) to back of sensors and magnets.

2B. Screws are also provided to mount sensors and magnets. Screws are preferred over the double- stick tape in permanent installations.

UL NOTE: Double-stick tape is not allowed in UL installations.

ATTACH SENSORS AND MAGNETS

Allow a maximum of 1/2" between magnet and sensor when door/window is closed.

The magnet height is adjustable and an optional magnet spacer is provided for uneven surfaces.

3A. On doors, mount sensor to door frame and magnet to door.

3B. On windows, mount sensor to window frame and magnet to window.

NOTE: Magnet must line up with mark on sensor case both horizontally & vertically.

4.Snap sensor onto mounting plate.

TEST SENSORS

INSTANT/DELAY

OPTION JUMPERSELECTS INSTANT

SELECTS

DELAY

ATTACH MOUNTING PLATES

USING THE SCREWS OR

DOUBLE-STICK TAPE PROVIDED

NOTE: ATTACHING THE TRANSMITTER WITH DOUBLE-STICK TAPE IS NOT ALLOWED IN UL INSTALLATIONS

In Chime Mode, the hardwired keypad(s) should “ding- dong” when the sensor sends a signal.

5.Open door or window.

Verify that light on the sensor (if there is one) glows momentarily when door/window is opened.

Status indicator on the hardwired keypad(s) should remain lit for each door/window sensor that is left open.

OPEN DOOR, TRANSMIT INDICATOR SHOULD LIGHT

ACTIVATE TRANSMITTER BY OPENING DOOR OR WINDOW

REPLACE TRANSMITTER COVER WHEN FINISHED

NOTE: THE TRANSMIT INDICATOR WILL ONLY LIGHT DURING TRANSMISSIONS WHEN THE CASE IS OPEN (EXCEPT WHEN PUSHING THE CASE FOR TESTING)