Linear DUAL 824 manual Or Quick Arm To Away Mode, EXIT DELAY For Leaving the Premises

Models: DUAL 824

1 48
Download 48 pages 4.08 Kb
Page 25
Image 25
AWAY MODE

AWAY MODE

Use this mode when no one will be staying home.

Away Mode causes an instant alarm when any perimeter sensor is triggered.

Away Mode causes a delayed alarm when any exit/entry sensor is triggered.

Away Mode causes an instant alarm when any interior sensors (motion detectors, etc.) are triggered. The interior sensors will be delayed if a perimeter delayed sensor is triggered first.

Each burglary sensor can trigger the siren once per arming period.

Alarm siren stops automatically after five minutes and the system will remain armed.

1A. Arm to Away Mode by entering a user code, and pressing AWAY.

1B. The user can “Quick Arm” to Away Mode from Home, Chime or Off Mode by pressing AWAY for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.)

EXIT DELAY (For Leaving the Premises)

When the system is armed to the Away Mode, the keypad(s) will sound a “Gong” and three “Beeps”.

During the 60 second Exit Delay, the keypad(s) will sound “Beeps” (double Beeps last 10 seconds) and the AWAY and ARMED indicators will blink.

2A. The Exit Delay gives the user 60 seconds to leave the premises through an exit/entry door without triggering an alarm.

2B. Re-entering during the Exit Delay will extend the Exit Delay another 60 seconds (one time only).

When the Exit Delay is over, the keypad(s) will sound one “Gong” to warn the user that the system is fully armed and the ARMED indicator will light steady.

NOTE: The Exit Delay time can be changed; see the “Advanced Programming” section of this manual.

ENTRY DELAY (For Entering the Premises)

3A. The Entry Delay gives the user 30 seconds to enter the premises through an exit/entry door without triggering an alarm.

3B. If a exit/entry sensor is triggered, starting the Entry Delay, the interior sensors will also become delayed (this allows motion in the premises during the Entry Delay).

During the 30 second Entry Delay, the keypad(s) will sound “Beeps”.

4.When the Entry Delay is over, the system will go into full alarm and sound the siren if it is not disarmed to the Off or Chime Mode.

If an alarm has occurred while the user was gone, multiple Beeps will sound after disarming and the sensor light for the sensor(s) that caused the alarm will fl ash (switch to Off Mode again or re-arm the Control Panel to stop the fl ashing alarm memory).

NOTE:The Entry Delay time can be changed; see the “Advanced Programming” section of this manual.

MANUAL BYPASSING OF SENSORS

Manual bypassing of sensors in the Away Mode allows arming of the system with open doors and windows, while still having perimeter protection with other closed doors and windows.

If the READY indicator is lit, all sensors are closed.

1. If the READY indicator is not lit, the system will resist arming because of open door or window sensors.

Four high-low Beeps to warn the user that something is open and the system will remain in the previous mode.

Lit sensor status indicators show which sensors are open.

2.To manually bypass the open sensors, arm the system again within five seconds.

A “Gong” and three “Beeps” will sound, the AWAY indicator will light, and the open sensors will be bypassed.

WARNING: Bypassed sensors cannot cause an alarm. Closing the sensor removes the bypass.

AWAY MODE

START IN OFF, CHIME EXIT DELAY (For Leaving the Premises) OR HOME MODE

(OPTIONAL)

YOUR

USER

CODE

1GONG & 3 BEEPS

DONE

OR QUICK ARM

TO AWAY MODE

START IN OFF, CHIME

ENTRY DELAY (For Entering the Premises) OR HOME MODE

HOLD DOWN

1 GONG & 3 BEEPS

DONE

23

Page 25
Image 25
Linear DUAL 824 Or Quick Arm To Away Mode, EXIT DELAY For Leaving the Premises, ENTRY DELAY For Entering the Premises