Linear DUAL 824 manual Test Mode, Sensor Function Table

Models: DUAL 824

1 48
Download 48 pages 4.08 Kb
Page 26
Image 26
TEST MODE

TEST MODE

Even though this is a self-monitoring supervised system, the National Burglar and Fire Alarm Association recommends that all security systems be tested manually on a regular basis.

1.The system must be in Off Mode before switching to Test Mode.

2.Switch the system into Test Mode by entering a user code and pressing TEST.

When the system is switched to the Test Mode, the keypad(s) will sound a “Gong” and four “Beeps”.

3.Holding down the TEST button in Test Mode will light all of the keypad’s indicators.

The sensor status indicators will fl ash for each sensor programmed into the Control Panel.

4.Go to each sensor and press its test button or open and close the protected opening.

5.To test the wireless keypad, press the wireless keypad’s SENSOR FUNCTION TABLE key.

The keypad(s) will make a “Bing” sound as each sensor is tested, followed by 1-3 beeps indicating signal strength with 3 beeps being the strongest signal.

As each sensor is tested, the sensor status indicator for the sensor will stop fl ashing and return to showing the current status of the sensor.

6.Continue testing until there are no flashing sensor status indicators.

NOTE: If the system is left unattended in Test Mode, it will automatically switch back to Off Mode after three minutes.

When directly connecting (without a telephone line) to the DUAL 824 with the RA-2400 remote access software (Version 1.3 or later), press the EMERGENCY key while in Test Mode to cause the control panel to connect to the modem.

TEST MODE

START IN OFF MODE

(OPTIONAL)

YOUR

USER

CODE

1GONG & 4 BEEPS

DONE

SENSOR OPERATION IN EACH SYSTEM MODE

SENSOR FUNCTION

OFF MODE

CHIME MODE

 

HOME MODE

AWAY MODE

 

 

 

 

 

AUTOMATION

 

ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT

 

 

 

 

 

EMERGENCY

 

ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM

 

 

 

 

 

PANIC

 

ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM

 

 

 

 

 

FIRE

 

ARMED 24-HOURS - TRIGGERS FIRE ALARM

 

 

 

 

 

 

PERIMETER

DEACTIVATED

CHIME

 

INSTANT BURGLARY ALARM

 

 

 

 

 

EXIT/ENTRY

DEACTIVATED

CHIME

 

DELAYED BURGLARY ALARM

 

 

 

 

 

 

 

 

 

 

 

INSTANT BURGLARY ALARM UNLESS

INTERIOR

DEACTIVATED

DEACTIVATED

 

DEACTIVATED

ACTIVATED DURING AN ENTRY

 

 

 

 

 

DELAY, THEN IT IS DELAYED

 

 

 

 

 

 

CHIME

 

 

CHIME

 

 

 

 

 

 

 

2-BUTTON ARM/DISARM (LEFT)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †

 

 

 

2-BUTTON AUTOMATION (RIGHT)

 

LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡

 

EMERGENCY (BOTH BUTTONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-BUTTON ARM (LEFT)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †

 

 

 

2-BUTTON DISARM (RIGHT)

 

RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡

 

EMERGENCY (BOTH BUTTONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

ENVIRONMENTAL

 

ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY

 

 

 

 

 

 

INTERIOR HOME

DEACTIVATED

DEACTIVATED

 

INSTANT BURGLARY ALARM

 

 

 

 

 

 

CAN BE HOME MODE USING PROGRAMMING STEP 50

‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

SENSOR FUNCTION TABLE

24

Page 26
Image 26
Linear DUAL 824 manual Test Mode, Sensor Function Table