GENERAL COMMUNICATOR OPTIONS

COMMUNICATOR ENABLE

The factory setting for the Control Panel disables the communicator. If the system is going to be a non-monitored, local alarm only, leave the communicator disabled.

STEP #107 If the system is going to be monitored by a Central Station, enable the communicator with this programming step.

PROGRAMMING STEP #107

ENTERS STEP NUMBER

0 FOR COMMUNICATOR OFF

1 FOR COMMUNICATOR ON

STORES VALUE - 1 BING

2-WAY AUDIO

When the Model VB-2 voice module is installed, the communicator can provide 2-way audio capability.

The audio module can be programmed for listen-only, 2-way manual operation (using a pushbutton telephone at the Central Station), and 2-way full duplex hands free operation.

Refer to the VB-2 installation instructions for details on operating the audio module.

NOTE: The Model VB-2 digital voice response module must be installed for this option to function.

The factory setting for the VB-2 audio module is OFF. STEP #76 The audio module can be set for (1) listen-only, (2)

2-way manual, (3) 2-way full duplex using this step.

NOTE: For safety, 2-way audio will not activate if the system is disarmed with the duress code.

NOTE:Units programmed for two-way duplex can still be controlled manually by pressing the “1” or “3” key. In addition, the Central Station can return the unit to two-way duplex by pressing the “8” key.

PROGRAMMING STEP #76

ENTERS STEP NUMBER

0 FOR NO AUDIO MONITORING

1 FOR LISTEN-ONLY

2 FOR 2-WAY MANUAL

3 FOR 2-WAY FULL DUPLEX STORES VALUE - 1 BING

VOICE RESPONSE

The Control Panel can be programmed to allow the keypad(s) speaker to play audio produced by the VB-2 digital voice response module.

This selection can also be used when a remote speaker is connected to the Control Panel.

The factory setting is to disable the keypad(s) speaker from playing voice module audio.

STEP #78 The Control Panel can be programmed to enable voice module audio using this step.

NOTE:Turning voice response OFF with this programming step will only effect the audio produced by the voice module. It will not stop the keypad(s) speaker from sounding local sirens and tones.

NOTE: A Model VB-2 digital voice response module must be installed for this option to function.

PROGRAMMING STEP #78

ENTERS STEP NUMBER

0 FOR NO VOICE RESPONSEE

1 FOR VOICE RESPONSE

STORES VALUE - 1 BING

REMOTE LOCKOUT

The factory setting for the communicator allows remote connection to the Control Panel with Linear's RA-2400 Remote Access Software and a modem (unlocked).

STEP #100 The Control Panel can be programmed to not answer incoming calls, thereby, not allowing remote access (locked) using this step.

PROGRAMMING STEP #100

ENTERS STEP NUMBER

0 FOR UNLOCK

1 FOR LOCK

STORES VALUE - 1 BING

37

Page 39
Image 39