SILENT BURGLARY ALARMS
✦The factory setting causes audible burglary alarms.
STEP #63 The Control Panel can be programmed for silent burglary alarms using this step.
PROGRAMMING STEP #63
PROGRAM
0 FOR AUDIBLE BURGLARY
1 FOR SILENT BURGLARY
STORE - 1 BING
SILENT EMERGENCY ALARMS
✦The factory setting causes audible emergency alarms.
STEP #64 The Control Panel can be programmed for silent emergency alarms using this step.
PROGRAMMING STEP #64
ENTERS STEP NUMBER
0 FOR AUDIBLE EMERGENCY
1 FOR SILENT EMERGENCY
STORES VALUE - 1 BING
DISABLING QUICK ARMING
✦The factory setting allows quick arming of the Control Panel by pressing down the mode keys for two seconds.
STEP #65 The Control Panel can be programmed to not allow quick arming using this step. If quick arming is disabled, a user code must be entered before pressing the mode buttons.
✎NOTE: For commercial installations with retail traffic, it is recommended to disable quick arming to prevent customers from arming the system.
✎NOTE: If quick arming is disabled the Home Instant Mode is unavailable.
PROGRAMMING STEP #65
ENTERS STEP NUMBER
0 FOR QUICK ARMING OFF
1 FOR QUICK ARMING ON
STORES VALUE - 1 BING
AUTOMATIC RESTORAL OF BYPASSED SENSORS
✦Bypassed sensors are ignored by the Control Panel and cannot cause an alarm.
✦The factory setting causes the Control Panel to automatically restore (remove the bypass from) sensors that close. After it's restored, the sensor is ready to cause an alarm the next time it is opened.
STEP #66 The Control Panel can be programmed to not automatically restore any bypassed sensor when the sensor closes using this step. Bypassed sensors will then remain bypassed until the system is disarmed.
✎ NOTE: This setting affects all sensors.
PROGRAMMING STEP #66
ENTERS STEP NUMBER
0 FOR AUTO RESTORAL OFF
1 FOR AUTO RESTORAL ON
STORES VALUE - 1 BING
AUTOMATIC BYPASSING OF OPEN SENSORS
✦The factory setting requires the user to manually bypass any open sensors when the system is armed.
✴If arming is attempted with open sensors, the keypad(s) will sound fi ve
✦Arming to the same mode again within five seconds will bypass any open sensors and arm the Control Panel.
STEP #67 The Control Panel can be programmed to automatically bypass any open sensors when the system is armed using this step.
✎ NOTE: This setting affects all sensors.
PROGRAMMING STEP #67
ENTERS STEP NUMBER
0 FOR AUTO BYPASS OFF
1 FOR AUTO BYPASS ON
STORES VALUE - 1 BING
32