2.SECURITY SYSTEM FLOOR PLAN

EXAMPLE SYSTEM

The example shows a typical DUAL 824 system.

Any or all of the accessories shown can be used.

A total of 24 sensors can be used with each Control Panel. Each wireless sensor, hardwired loop, and wireless keypad used occupies a sensor location.

DESIGN THE INSTALLATION

1.Draw a floor plan for the installation.

2.Consider the security needs of the premises.

3.Determine which doors and windows are vulnerable to intrusion.

4.Figure which interior areas an intruder might go to if unlawful entrance is gained.

5.Indicate locations for door/window sensors, interior motion detectors, wireless and hardwired keypads, glass break detectors and external siren speakers.

6.Decide on a centralized location for the security Control Panel.

ES

 

 

 

 

MD

GB

S

S

MS

 

 

HK

 

 

 

LIVING

ENTRY

 

 

S

 

 

 

 

 

 

 

 

 

 

 

MS

 

 

 

 

KITCHEN

S BED

 

DINING

 

CO

 

 

 

 

S

 

 

 

MS

 

 

 

HK

 

SD

 

 

BATH

BED

 

S

 

 

 

 

 

 

CP - CONTROL PANEL HK - HARDWIRED KEYPAD

S - DOOR/WINDOW SENSOR WK - WIRELESS KEYPAD MD - MOTION DETECTOR ES - EXTERNAL SIREN

SD - SMOKE DETECTOR

CO - CARBON MONOXIDE DETECTOR GB - GLASS BREAK SENSOR

MS - HARDWIRED MAGNETIC SWITCH

S

S

DEN

CP

 

 

NOTE: IN NEW CONSTRUCTION, NFPA 72 REQUIRES A SMOKE DETECTOR LOCATED INSIDE EACH BEDROOM AS WELL AS A SMOKE DETECTOR ON EACH LEVEL.

WK

S

GARAGE

GB

MD

Example Residential Security System Floor Plan

4

Page 6
Image 6
Linear DUAL 824 manual Security System Floor Plan, Example System, Design the Installation