14.COMMUNICATOR PROGRAMMING

14.COMMUNICATOR PROGRAMMING

To perform any of the advanced programming steps, the system must be in the Setup Mode.

Each programming function is performed with similar keystrokes. After the system is in Setup Mode, enter the programming step number and press HOME, then enter the new value and press AWAY. For reference, follow the figures next to the programming steps.

If the new value is accepted, a “Bing” will sound. If the new value is not accepted, a “Double Buzz” will sound.

SETUP MODE

1.Start with the system in Test Mode (Setup Mode cannot be reached from any other mode).

2.From Test Mode, enter the master user code then press TEST.

NOTE: Only the master user code can be used to put the system into the Setup Mode. The restricted user codes cannot access Setup Mode, only Code Mode.

A “Gong” and fi ve “Beeps” will sound, signaling that the system is in Setup Mode.

3.After programming changes are complete, press the OFF key for three seconds to exit Setup Mode.

NOTE: If the system is left unattended in Setup Mode, it will automatically switch back to Off Mode after three minutes.

ENTERS PROGRAM STEP NUMBER TO MODIFY

General Communicator Programming Table STORES NEW VALUE

START IN TEST

MASTER

USER

CODE

1 GONG & 5 BEEPS (SETUP MODE)

GENERAL COMMUNICATOR OPTIONS

STEP #

PROGRAMMING

 

POSSIBLE

FACTORY

INSTALLATION

 

FUNCTION

 

VALUES

VALUE

VALUE

 

 

 

 

 

76

2-WAY AUDIO

0= NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX

0

 

 

 

 

 

 

 

78

VOICE RESPONSE FROM KEYPAD SPEAKER

0

= VOICE RESPONSE DISABLED

0

 

1

= VOICE RESPONSE ENABLED

 

 

 

 

 

 

 

 

 

 

 

100

REMOTE PROGRAMMING LOCKOUT

0

= UNLOCK; 1 = LOCK

0

 

 

 

 

 

 

 

101

CALL LIMITER

0

= OFF; 1 = FIVE CALLS PER ARMING PERIOD

0

 

 

 

 

 

 

 

103

DIALING DELAY

0

= NO DELAY; 1 = 30 SECOND DELAY

0

 

 

 

 

 

 

 

104

DIALING METHOD

0

= TONE; 1 = PULSE

0

 

 

 

 

 

 

 

107

COMMUNICATOR ENABLE

0

= COMMUNICATOR OFF; 1 = COMMUNICATOR ON

0

 

 

 

 

 

 

 