3-3.Configuration Properties

 

Item

Description

 

nc

Name

 

 

No.

 

 

 

 

 

 

 

 

 

 

1

Minimum Send Time

Set the minimum transmission interval between output network variables.

 

nc15

nciMinOutTm

 

SNVT_time_sec

 

 

 

 

 

2

Send Heartbeat Start Time

Set the start time of network variable change at power ON.

 

nc16

nciStartHrtBt

 

SNVT_time_sec

 

 

 

 

 

3

Send Start Time

Set the automatic update start time at power ON.

 

nc17

nciStartOutTm

 

SNVT_time_sec

 

 

 

 

 

4

Initialize Start Time

Set the start time of initial output change at power ON.

 

nc18

nciInitStartTm

 

SNVT_time_sec

 

 

 

 

 

5

Initialize Send Time_1

Set the minimum transmission interval between output network variables

 

nc19

nciInitOutTm_1

at initial output.

 

SNVT_time_sec

 

 

 

 

6

Initialize Send Time_2

Set the minimum transmission interval between each unit during initial

 

nc20

nciInitOutTm_2

output.

 

SNVT_time_sec

 

 

 

 

7

Send Heartbeat_1

Set the output network variable's update interval.

 

nc21

nciSndHrtBt_1

 

SNVT_time_sec

 

 

 

 

 

8

Send Heartbeat_2

Set the output network variable's update interval.

 

nc22

nciSndHrtBt_2

 

SNVT_time_sec

 

 

 

 

 

9

Spacetemp Width

Set the minimum fluctuation width of the output when the indoor

 

nc24

nciAnalogWidth

temperature state output changes.

 

SNVT_temp_p

 

 

 

 

10

Monitoring Time

Set the set time monitor interval of the indoor temperature for the indoor

 

nc25

nciAnlgMonTm

unit.

 

SNVT_time_sec

 

 

 

 

11

Receive Heartbeat_1

Set the maximum elapse time from the previous update.

 

nc26

nciRcvHrtBt_1

 

SNVT_time_sec

 

 

 

 

 

12

Receive Heartbeat_2

Set the maximum elapse time from the previous update.

 

nc27

nciRcvHrtBt_2

 

SNVT_time_sec

 

 

 

 

 

13

Effective Time_1

Set the effective time for the emergency stop command.

 

nc28

nciEffectTm_1

 

SNVT_time_sec

 

 

 

 

 

14

Effective Time_2

Set the effective time for the collective operation prohibit command.

 

nc29

nciEffectTm_2

 

SNVT_time_sec

 

 

 

 

 

15

Effective PollFetch

Set the presence of a response for poll (Fetch) requests in respect to the

 

nc30

nciPollFetch

output network variables.

 

SNVT_switch

 

 

 

 

16

Effective Offline Mode

Set the validity of the offline mode at power ON.

 

nc31

nciOffline

 

SNVT_switch

 

 

 

 

 

17

Lower Setpoint Cooling

Set the cool/dry lower limit temperature setting value for the local remote

 

nc34

nciCoolLrSetP

controller.

 

SNVT_temp_p

 

 

 

 

18

Upper Setpoint Heating

Set the heat upper limit temperature setting value for the local remote

 

nc35

nciHeatUpSetP

controller.

 

SNVT_temp_p

 

 

 

 

19

Local Operation Lock

Set the simple lock setting value for the local remote controller.

 

nc36

nciRmOpLck

 

SNVT_switch

 

 

 

 

 

20

Local Display_1

Set the validity of the automatic actual operation mode display for the local

 

nc37

nciRmDsp_1

remote controller.

 

SNVT_switch

 

 

 

 

21

Local Display_2

Set the validity of the intake temperature display for the local remote

 

nc38

nciRmDsp_2

controller.

 

SNVT_switch

 

 

 

 

22

Communication Timing

Set the networks communication start timing.

 

nc39

nciSet_1

 

SNVT_switch

 

 

 

 

 

Valid Range

Unit,

 

Default

Page.

 

 

 

 

 

 

 

 

1.0 to 600.0 seconds

1sec

6553.5 seconds (invalid)

36

 

 

 

 

1200.0 to 6540.0 seconds

60sec

6553.5 seconds (As 1800 seconds)

37

 

 

 

 

1200.0 to 6540.0 seconds

60sec

6553.5 seconds (As 1800 seconds)

37

 

 

 

 

0.0 second1200.0 to 3600.0 seconds

60sec

6553.5 seconds(invalid)

38

 

 

 

 

0.0 second0.1 to 1.0 seconds

0.1sec

6553.5 seconds (invalid)

39

 

 

 

 

0.0 second5.0 to 50.0 seconds

1.0sec

6553.5 seconds (invalid)

39

 

 

 

 

0.0 second600.0 to 6540.0 seconds

60sec

6553.5 seconds (invalid)

40

 

 

 

 

SW1-3 is OFF0.0 second600.06540.0 seconds

10sec

6553.5 seconds (invalid)

40

SW1-3 is ON0.0 second60.0 to 6540.0 seconds

 

 

 

 

0.5 to 2.0

0.5

-0.01(As 1.0)

41

 

 

 

 

 

SW1-3 is OFF0.0 second600.0 to 6540.0

10sec

6553.5 seconds (As 600.0 seconds)

41

seconds

 

 

 

 

600.0 to 6540.0 seconds

60sec

0.0 second (As 1800.0 seconds)

42

 

 

 

 

600.0 to 6540.0 seconds

60sec

0.0 second (As 1800.0 seconds)

42

 

 

 

 

60.0 to 6540.0 seconds

60sec

6553.5 seconds (As 600.0 seconds)

43

 

 

 

 

60.0 to 600.0 seconds

60sec

6553.5 seconds (As 600.0 seconds)

43

 

 

 

 

 

State=0(Response)1(non-response)

--

0(disable)

*Always effective

44

 

 

 

 

 

State=0(disable)1(enable)

--

0(disable)

*Always effective

45

 

 

 

 

19.0to 30.0

1.0

- 0.01(As 19)

46

 

 

 

 

17.0to 28.0

1.0

- 0.01(As 28)

46

 

 

 

 

State=0(All button)、1except Start/Stop button)

--

0(All button)

46

 

 

 

 

 

State=0(display)1(no display)

--

0(display)

 

47

 

 

 

 

 

State=0(display)1(no display)

--

0(display)

 

47

 

 

 

 

 

State=0(initialize)1(setting time)

--

0(initialize)

 

48

 

 

 

 

 

WSN02-2124