GT10/GT30

6.2 Entering Configuration Settings with GTWIN

 

 

in the initial address of the word device under “Basic Communication Area to PLC” in the “Basic Setup” parameters under “GT Configuration” will be displayed.

This function is used when it is necessary to delay the start–up time when the power supply on the PLC side is turned on.

CAUTION

Communication between the GT30 and the PLC (external device) cannot be carried out during the time specified by the “Display Time” parameter.

6.2.6GT Configuration Settings: “Setup”

Clicking on the “Setup” tab in the “GT Configuration” dialog box displays the screen shown below. Here, clock functions, backlight control, and other parameters can be specified.

“Setup” screen

Clock

Clock

This is used to specify the reference destination for the clock displayed with the GT30. Select one of the radio buttons.

GT Clock ––– When the time is displayed, the internal clock in the GT30 is used as a reference for the value.

PLC Clock ––– When the time is displayed, the internal clock in the PLC is used as a reference for the value.

If the “PLC Clock” is referenced for the clock setting, clicking on the button displays a screen where the type of device and the address can be specified.

102