Includes installation guide for GTWIN screen creation software
SAFETY PRECAUTIONS
[ALWAYS OBSERVE THESE PRECAUTIONS]
WARNING
CAUTION
How This Manual Is Configured
GT10/GT30 Main Unit
Screen Creation Tool Terminal GTWIN
Table of Contents
Part
GT10, GT30 Main Unit
Chapter
Specifications
Chapter 2 Installation and Wiring
Chapter 3 Setup
Chapter 4 Connecting and Communicating with the PLC
Chapter 5 GT10 Configuration Settings
GT30 Configuration Settings
Chapter 7 How the Various Functions Are Used
Chapter 8 Servicing and Maintenance
Chapter 9 Troubleshooting
Chapter 10 Preparing GTWIN
Appendix A Code Tables
Index
Record of Changes
Page
Page
Before Using the GT10/GT30
GT10/GT30 Usage Procedures
Procedure For Using the GT10/GT30
7. Install the screen creation tool
8. Create the screen contents
9. Test the operation
Confirming the Package Contents
Items Included with the GT10 (AIGT1000B)
Items Included with the GT30 (AIGT3100B/AIGT3300B)
Items Included with the Terminal GTWIN English–languageversion (AIGT8001V2)
Items Included With the PLC Connection Cable (AIGT8192 / AIP81842D)
Items Included with the Front Panel Protective Sheet (AIGT180/AIGT380)
GT Series System Configuration
Page
Products for the GT Series
Safety Precautions
Special Items
Page
Specifications
1.1GT10/GT30 Specifications
1.1.1General Specifications
1.1.2Display
1.1.3Functions
Touch Key
Memory (1)
1.1.6Memory (2)
1.1.7Interface
1.2GT10 Names and Functions of Parts
1.2.1GT10 (front)
1.2.2GT10 (rear)
1.2.3Names and Functions of Parts
(2) Front panel protective sheet
(3) Power supply terminal
(4) COM. port (PLC/external device connection port)
(5) TOOL port (GTWIN connection port)
(6) Operation mode setting switches
1.3GT30 Names and Functions of Parts
1.3.1GT30 (front)
1.3.2GT30 (rear)
1.3.3Names and Functions of Parts
Page
1.4Internal Wiring Connections for Ports
1.4.1COM. Port
1.4.2TOOL Port
1.4.3Power Supply Terminals
1.5Dimensions
1.5.1GT10 Dimensions
1.5.2GT10 Panel Cutout Dimensions
1.5.3GT30 Dimensions
1.5.4GT30 Panel Cutout Dimensions
Page
Installation and Wiring
2.1Installation
2.1.1Installation Environment
2.1.2GT10 Installation Method
Page
2.1.3GT30 Installation Method
Page
2.2Wiring the Power Supply
Keep the power supply wiring separate
2.3Wiring the COM. Port
2.3.1Wiring Method
2.3.2Precautions Concerning Wiring
Setup
3.1Setup Procedure for the GT10
(3) Transfer the GT10 Configuration file from GTWIN
Boot GTWIN, and select “Transfer” on the “File” menu
(4) Setup is completed
Backup of the GT10 Configuration file
3.2Setting the Basic Communication Area, GT10 and PLC
3.2.1What is the Basic Communication Area
3.2.2GT10 Basic Communication Area Map
Screen no. specified by PLC
No. of currently displayed screen
Forced–Display
Backlight Valid flag
Backlight Flashing
sub–menu.Turn on the radio button for “IOP01 Mode” in the displayed dialog box
For information on the displayed dialog box, please see “Basic
Setup” under “GT10 Configuration Settings” on page
NOTES
Page
3.3Setup Procedure for the GT30
(3) Transfer the GT30 Configuration file from GTWIN
Backup of the GT30 Configuration file
3.4Setting the Basic Communication Area, GT30 and PLC
3.4.1What is the Basic Communication Area
3.4.2GT30 Basic Communication Area Map
BAT LOW flag
Page
Connecting and Communicating with the
PLC
4.1Connecting the FP–Sigma
4.1.1Connecting to the COM. Port
4.1.2Connecting to the TOOL Port
PLC communication cable: Mini–DIN 5–pin loose–wirecable (AIGT8192)
Connecting to the FPΣ TOOL port
4.2Connecting the FP0
4.2.1Connecting to the COM. Port
4.2.2Connecting to the TOOL Port
Connecting to the FP0 TOOL port
4.3Connecting the FP1
4.3.1Connecting to the COM. Port
4.4Connecting the FP2/FP2SH
4.4.1Connecting to the COM. Port
4.4.2Connecting to the TOOL Port
4.5Connecting the FP2/FP2SH CCU
4.6Connecting the FP10SH
4.6.1Connecting to the COM. Port
4.6.2Connecting to the TOOL Port
Connecting to the FP10SH TOOL port
4.7Connecting the FP10SH/FP3 CCU
4.8Connecting the FP–M
4.8.1Connecting to the COM. Port
4.8.2Connecting to the TOOL Port
4.9Automatic Communication Settings Function
Page
4.10 Through Function
Page
4.11 Connecting with a PLC by Mitsubishi Electric Corp
4.11.1FX Series
Page
4.12 Connecting with a PLC by Omron Corp
4.12.1SYSMAC C Series, α Series, CV Series, and CS1 Series
Page
Page
SYSMAC CV series (using link interface)
Using the SYSMAC CS1 series (1 : 1)
Setting the communication conditions for the GT main unit
Setting the communication conditions for the PLC
Communicating with the RS232C port of the CPU unit
Communicating with a communication port
Communicating with a higher–orderlink interface unit
Page
GT10 Configuration Settings
5.1GT10 Configuration Settings
5.1.1Two Types of GT10 Configuration Settings
5.2Entering Configuration Settings with GTWIN
5.2.1Opening the GT Configuration Settings
5.2.2GT Configuration Settings: “Basic Setup”
“Basic Setup” screen
Title
PLC Model
GT Model
Modes
5.2.3GT Configuration Settings: “Communication Parameters”
“Communication Parameters” screen
COM. port (Connected to PLC/External Device)
Handle Communication Error
“Communication Error Remedy” dialog box
5.2.4GT Configuration Settings: “Auto–Paging”
“Auto–Paging”screen
Auto–paging
Auto–pagingsettings
Time
Jump to
5.2.5GT Configuration Settings: “Startup Screen Settings”
5.2.6GT Configuration Settings: “Setup”
Device Setting dialog box
Transfer Outside
Auto–Off
5.2.7GT Configuration Settings: “Hold PLC Device”
5.2.8GT Configuration Settings: “GT Internal Device Hold”
GT internal devices
5.3Entering Configuration Settings from the GT10
5.3.1What is the System Menu
5.3.2Bringing Up the System Menu
5.3.3Setting Mode: “Communication Parameters” (COM. Port / TOOL Port)
5.3.4Setting Mode: “Liquid Crystal Display Contrast Adjustment” (Contrast)
5.3.5Setting Mode: “Clock Settings” (Clock)
5.3.6Setting Mode: “Memory Initialization” (Clear Memory)
5.3.7Test Mode: “Self–Diagnosis”
Touch SW
B. Light
Buzzer
LCD
Contrast
5.3.8Inhibiting the System Menu Display
Page
GT30 Configuration Settings
6.1GT30 Configuration Settings
6.1.1Two Types of GT30 Configuration Settings
6.2Entering Configuration Settings with GTWIN
6.2.1Opening the GT Configuration Settings
6.2.2GT Configuration Settings: “Basic Setup”
PLC Model
GT Model
6.2.3GT Configuration Settings: “Communication Parameters”
Page
6.2.4GT Configuration Settings: “Auto–Paging”
Page
6.2.5GT Configuration Settings: “Startup Screen Settings”
6.2.6GT Configuration Settings: “Setup”
Page
6.2.7GT Configuration Settings: “Hold PLC Device”
6.2.8GT Configuration Setting: “GT Internal Device Hold”
GT internal device hold screen
Data register
Don’t hold
Hold
Internal relay
Page
6.3Entering Configuration Settings from the GT30
6.3.1What is the System Menu
6.3.2Bringing Up the System Menu
6.3.3Setting Mode: “Liquid Crystal Display Contrast Adjustment”
6.3.4Setting Mode: “Clock Settings” (Clock)
Setting the day
The day is set automatically, based on the year, month, and date data
6.3.5Setting Mode: “Communication Parameters” (TOOL Port / COM. Port)
6.3.6Setting Mode: “Memory Initialization” (Clear Memory)
6.3.7Test Mode: “Self–Diagnosis”
6.3.8Inhibiting the System Menu Display
How the Various Functions Are Used
7.1Switching Screens
7.1.1Switching the Screen from the PLC
7.1.2Switching the Screen with the GT Main Unit
Function switching parts: Attribute editing dialog box
(1) Using the “Change Screen” operation mode
(2) Using the “Value Set” operation mode
Using the auto–pagingfunction
If the screen does not change as expected
Page
Page
7.2GT10 Bit Device Functions
Using a flashing backlight
Making the buzzer sound
Data Input in Progress flag
7.3GT30 Bit Device Functions
Page
Page
Servicing and Maintenance
8.1The Internal Secondary Battery (GT10)
Page
8.2Battery (GT30)
8.3Replacing the Front Panel Protective Sheet
8.4Replacing the Waterproof Packing
8.5Replacing the Backlight (GT30 Only)
Page
Troubleshooting
9.1What to Do If Something Unusual Occurs (GT10)
Page
Page
9.2What to Do If Something Unusual Occurs (GT30)
Page
Page
9.3Error Codes and How to Handle Them
9.3.1GT Series Error Codes
Connecting to a PLC made by Omron
9.3.2PLC Error Codes
9.4GT10 Screen Messages
9.5GT30 Screen Messages
Page
Before Using Terminal GTWIN
Precautions Before Using GTWIN
Special Precautions
Preparing GTWIN
10.1 Installing GTWIN
Page
8.Confirm the licensing agreement by clicking [Yes]
9.Register the user information
Never eject the CD during the installation process
10.Click [Next]
11.Select the installation destination
12.Select the program folder
13.After selecting a program folder, click [Next]
14.When this screen is displayed, click [OK]
15.Reboot the computer
10.2 Booting GTWIN
10.2.1Selecting the Working Menu
10.2.2Selecting the Model
10.2.3Entering Settings for the Basic Communication Area to PLC
10.3 Exiting GTWIN
10.4 Procedures for Using GTWIN
Opening and closing base screens
Copying, moving, and deleting base screens
Displaying the Screen Manager
6.Create the text and graphics for the screen
Writing text
8.Save the screen file
9.Transfer the file to the GT
10.Print the screen contents
Page
Appendix A
Code Tables
A.1 BIN/HEX/BCD Code Correspondence Table
A.2 ASCII Code Table
Page
Index
Page
Record of Changes