GT10/GT30

4.8 Connecting the FP–M

 

 

4.8Connecting the FP–M

4.8.1Connecting to the COM. Port

GT10

GT30

 

 

FP–M COM. port

AIP81842D

 

 

 

 

 

 

 

 

 

 

 

 

FP–M communication format settings

 

System register no.

Item

Value Set

System register value

412

Selection of target use of RS232C port

Computer link

K1

413

Data length

8 bits

K3

 

 

 

 

 

Parity check

Yes

 

 

 

 

 

 

Parity setting

Odd

 

 

 

 

 

 

Stop bits

1 bit

 

 

 

 

 

 

Line return code

CR

 

 

 

 

 

 

Start code

No STX

 

414

Baud rate setting

19200 bits/s

K0

415

Unit number

1

K1

416

Modem connection

No connection

H0

 

 

 

 

PLC communication cable: D–sub 9–pin loose–wire cable (AIP81842D)

 

2000mm

Signals on D–sub side

 

 

 

 

 

35mm

Pin no.

Wire color

GT COM port

 

5mm

1

 

––

––

 

2

 

White

RD

 

1

 

6

3

 

Green

SD

2

 

7

4

 

 

––

3

 

 

8

4

5

 

 

––

9

 

 

 

5

6

 

––

––

 

 

 

 

Wires’ cross section: 0.25mm2

7

 

Brown

GND

 

8

 

––

––

 

 

9

 

––

––

 

 

Specifications

Length

Product no.

 

 

D–sub 9–pin

 

2m

AIP81842D

 

 

Single–side

 

 

 

 

 

loose wiring

 

 

 

56