GT10/GT30

9.2

What to Do If Something Unusual Occurs (GT30)

 

 

 

 

 

 

 

 

 

 

Problem

Cause

 

Solution

Related

 

 

 

 

 

Screen is

1) The power voltage may be low.

 

1) Supply 24V DC 0.5 A.

page 21

dim

2) The contrast is set too low.

 

2) Bring up the system menu and adjust

page 126

 

 

 

3) The backlight is off due to the [Back-

 

the contrast.

 

 

 

 

 

 

light Auto–off] setting in the [Setup] of

 

3) Touching any area of the screen lights

page 121

 

the GT30 configuration settings in

 

that area. If a switch part is set on the

 

 

GTWIN.

 

touched area, the area will not light

 

 

 

 

even if touched. To change the setting,

 

 

 

 

change the content of the backlight

 

 

 

 

auto–off settings.

 

 

 

 

 

 

Backlight

The backlight auto–off timer setting is too

 

Change the backlight auto–off timer set-

page 121

goes off too

short.

 

ting.

 

quickly

 

 

 

 

 

 

 

 

 

Date / time

1) The GT30 internal clock is incorrect.

 

1) Bring up the system menu and adjust

page 127

display is

2) No battery has been inserted.

 

the clock.

 

incorrect

 

2) Open the cover on the option compart-

page 130

3) The battery insulation sheet has not

 

 

 

 

 

ment and install a battery.

 

 

been removed.

 

 

 

 

3) Open the cover on the option compart-

 

 

4) The battery has run down.

 

 

 

 

ment and remove the battery insula-

 

 

5) The PLC’s internal calendar timer

 

 

 

 

tion sheet.

page 130

 

used as a reference is incorrect.

 

4) Replace the battery.

 

 

 

 

 

 

 

 

5) Adjust by rewriting the value in the

 

 

 

 

PLC’s internal calendar timer.

 

 

 

 

 

All PLC

 

 

 

 

manuals

 

 

 

 

 

Hold PLC

1) No battery has been inserted.

 

1) Open the cover on the option compart-

page 130

Device data

2) The battery insulation sheet has not

 

ment and install a battery.

 

content isn’t

 

 

 

been removed.

 

2) Open the cover on the option compart-

 

saved

 

 

3) The battery has run down.

 

ment and remove the battery insula-

 

 

 

 

 

 

tion sheet.

page 130

 

 

 

 

 

 

3) Replace the battery.

 

 

 

 

 

 

Touch panel

1) The switch part size setting does not

 

1) When creating screens with GTWIN,

GTWIN HELP

doesn’t work

match the touch panel grid.

 

match grid settings to touch panel and

 

 

2) Valid conditions have been set for the

 

make them valid, then resize.

 

 

 

 

 

 

switch part, but those conditions have

 

2) Check that the device status condi-

GTWIN HELP

 

not been met. (Applies only to custom

 

tions on the PLC side are valid.

 

 

parts.)

 

 

 

 

 

 

 

 

No operating

1) The [Switch Sounds] setting under

 

1) Change the setting to [Enabled].

GTWIN HELP

sounds are

[Options] in the switch part attributes

 

2) Change the setting to [Enabled].

page 122

heard when

is set to [Disabled].

 

 

 

 

the touch

2) The [Touch Sounds] setting under

 

 

 

panel is

 

 

 

[Setup] in the GT30 configuration set-

 

 

 

pressed.

 

 

 

tings in GTWIN is set to [Disabled].

 

 

 

 

 

 

 

 

 

 

 

 

Buzzer

Bit F of the first word in the basic com-

 

Set the F bit to OFF on the PLC side.

page 124

sounds

munication area bit device is set to ON.

 

(Do not use the basic communication

 

continuously

 

 

area with ladder programs.)

 

 

 

 

 

 

Backlight

Bits C and D, of the first word (backlight

 

Perform correct bit operations on the

page 124

color

flashing setting) in the basic communica-

 

PLC side. (Do not use the basic commu-

 

changes /

tion area bit device are set to ON.

 

nication area with ladder programs.)

 

flashes

 

 

 

 

 

 

 

 

 