FTroubleshooting the MVME177:

Solving Startup Problems

F

Try these simple troubleshooting steps before calling for help or sending your CPU board back for repair.

Some of the procedures will return the board to the factory debugger environment. (The board was tested under these conditions before it left the factory.)

Selftest may not run in all user-customized environments.

Table F-1. Basic Troubleshooting Steps

Condition ...

Possible Problem ...

Try This ...

 

 

 

I. Nothing works,

A. If the RUN or +12V

1. Make sure the system is plugged in.

no display on the

LED is not lit, the

2. Check that the board is securely installed in

terminal.

board may not be

its backplane or chassis.

 

getting correct power.

3. Check that all necessary cables are

 

 

 

 

connected to the board, per this manual.

 

 

4. Check for compliance with System

 

 

Considerations, per this manual.

 

 

5. Review the Installation and Startup

 

 

procedures, per this manual. In most cases,

 

 

this includes a step-by-step powerup routine.

 

 

Try it.

 

 

 

 

B. If the LEDs are lit,

1. For VMEmodules, the CPU board should be

 

the board may be in

in the Þrst (leftmost) slot.

 

the wrong slot.

2. Also check that the Òsystem controllerÓ

 

 

function on the board is enabled, per this

 

 

manual.

 

 

 

 

C.The Òsystem

ConÞgure the system console terminal per this

 

consoleÓ terminal

manual.

 

may be conÞgured

 

 

wrong.

 

 

 

 

F-1

Page 161
Image 161
Motorola MVME177 manual Table F-1. Basic Troubleshooting Steps, Condition Possible Problem Try This