Motorola MVME177 manual Disk/Tape Controller Modules Supported, First Second Controller Type

Models: MVME177

1 171
Download 171 pages 43 Kb
Page 139
Image 139

CDisk/Tape Controller Data

C

Disk/Tape Controller Modules Supported

The following VMEbus disk/tape controller modules are supported by 177Bug. The default address for each controller type is First Address. The controller can be addressed by First CLUN during:

Command BH

Command BO

Command IOP

TRAP #15 calls .DSKRD or .DSKWR

Note that if another controller of the same type is used, the second one must have its address changed by its onboard jumpers and/or switches, so that it matches Second Address and can be called up by Second CLUN.

 

First

First

Second

Second

Controller Type

CLUN

Address

CLUN

Address

CISC Single Board Computer (SBC)

$00

--

--

--

 

(Note 1)

 

 

 

MVME320 - Winchester/Floppy Controller

$11

$FFFFB000

$12 (Note

$FFFFA000

 

(Note 2)

 

2)

 

 

 

 

 

 

MVME323 - ESDI Winchester Controller

$08

$FFFFA000

$09

$FFFFA200

 

 

 

 

 

MVME327A - SCSI Controller

$02

$FFFFA600

$03

$FFFFA700

MVME328 - SCSI Controller

$06

$FFFF9000

$07

$FFFF9800

 

 

 

 

 

MVME328 - SCSI Controller

$16

$FFFF4800

$17

$FFFF5800

 

 

 

 

 

MVME328 - SCSI Controller

$18

$FFFF7000

$19

$FFFF7800

MVME350 - Streaming Tape Controller

$04

$FFFF5000

$05

$FFFF5100

 

 

 

 

 

Notes: (1) If the SBC (e.g., an MVME177) SCSI port is used, then the SBC module has CLUN 0.

(2)For SBCs, the Þrst MVME320 has CLUN $11, and the second MVME320 has CLUN $12.

C-1

Page 139
Image 139
Motorola MVME177 manual Disk/Tape Controller Modules Supported, First Second Controller Type